ArticleRSC advances2025
Facile electrochemical determination of acetaminophen at micromolar levels utilizing conjugated bimetallic Co-Zn porphyrin polymer electrodes as sensing platforms.
Article in RSC advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The increasing threat of pharmaceutical pollution to public health and the environment is a critical issue. This research endeavors to tackle the challenge by developing an advanced electrochemical sensor for the accurate detection of acetaminophen (APAP). A highly sensitive electrochemical sensor, based on a porphyrin polymer, was designed for this purpose. The study shows that the bimetallic structure of the polymer significantly enhances the sensing efficiency of micropollutants. By analyzing its electrochemical properties, the sensor achieved an impressive detection limit of 0.46 μM for APAP, with a linear detection range from 4 to 1000 μM. The sensor also demonstrated strong anti-interference capabilities, along with high reproducibility and stability. Furthermore, it exhibited excellent performance in analyzing actual samples. Compared with single-metal polymer materials, bimetallic polymer materials exhibit the lowest charge transfer resistance, rapid electron transfer rates, and large electrochemical active areas, thereby enabling superior sensing capabilities.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.