Evidence map›Paper›PMID 40551178›Full record

Observational studyJournal of orthopaedic surgery and research2025

The influence of the interfacing angle between the pedicle screw and support rods on the clinical outcomes after posterior lumbar-sacral topping-off surgery: A retrospective clinical study.

Mingzheng Zhao, Honghao Yang, Shixuan Guo, Fengqi Cheng, Yaoshen Zhang, Yong Hai, Yuzeng Liu

Abstract readObservational Study
In one paragraph

Observational study in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mingzheng ZhaoDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China.
Honghao YangDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China.
Shixuan GuoDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China.
Fengqi ChengDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China.
Yaoshen ZhangDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China. zhangyaoshen08@163.com.
Yong HaiDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China. yong.hai@ccmu.edu.cn.
Yuzeng LiuDepartment of Orthopedic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, No. 8 Gongtinanlu, Beijing, 100020, China. beijingspine2010@163.com.

Funding

Clinical Research Incubation Program of Beijing Chao-Yang Hospital CYFH202316National Clinical Medical Research Center of Orthopedics and Sports Rehabilitation Innovation Fund 2021-NCRC-CXJJPY-17
6 · The paper itself

Abstract

backgroundThe mismatch in the pedicle screw/rod interface angle is a common phenomenon after topping-off surgery, indicating that the implants were assembled under mechanical stress, which may negatively impact clinical outcomes. PURPOSE: This study aims to assess the incidence of postoperative screw/rod mismatch and its effect on clinical outcomes, including (1) Adjacent segment degeneration (ASD); (2) Screw loosening and rod breakage; (3) Visual analogue scale (VAS) scores; and (4) Oswestry disability index (ODI) scores.

methodsThis study is a monocentric retrospective observational study that included patients diagnosed with lumbosacral degenerative disease and underwent topping-off surgery. The outcome measures encompass: interfacing angle mismatch between pedicle screws and support rods, incidence of proximal ASD, screw loosening and rod breakage, VAS scores, and ODI scores. The impact of screw–rod interfacing angle mismatch on the development of postoperative ASD was further analyzed using univariate and multivariate logistic regression analysis. Postoperatively, lateral X-rays and CT scans were used for measurements. The interfacing angle mismatch between the pedicle screw and rod is measured as the angle between two parallel lines on either side of each pedicle screw head and a line laterally along the associated rod. Bonferroni correction was applied to counteract multiple comparisons, with the adjusted significance level set at *p < 0.05.

resultsAmong the 237 patients who underwent topping-off surgery, 84 cases (35.44%) exhibited a mismatch in the interfacing angle between the pedicle screw and the support rod, involving 114 out of 1,208 screws (9.44%). After a mean follow-up period of 26.57 ± 2.88 months, the overall incidence of adjacent segment degeneration (ASD) was 9.28% (22/237), screw loosening occurred in 12.66% of patients (30/237), and rod breakage occurred in 2.53% (6/237).In patients with interfacing angle mismatch, the incidence of ASD was significantly higher, reaching 21.4% (18/84), compared to 2.6% (4/153) in patients without mismatch (P < 0.001). The increase in screw loosening was even more pronounced, with a rate of 28.6% (24/84) in the mismatch group versus only 3.9% (6/153) in the matched group (P < 0.001).There was no significant difference in rod breakage rates between the two groups (2.0% vs. 3.6%, P = 0.361). Additionally, patients with angle mismatch had significantly higher VAS scores than those without mismatch (3.63 ± 0.93 vs. 2.19 ± 0.78, P < 0.001). However, there was no statistically significant difference in ODI scores between the two groups (19.26 ± 2.51 vs. 19.70 ± 2.62, P = 0.214).

conclusionA mismatch in the interfacing angle between the pedicle screw and the support rod may contribute to a higher incidence of ASD, increased screw loosening, and more severe postoperative pain following topping-off surgery. Refined preoperative planning of screw trajectories and precise intraoperative techniques are essential to optimize clinical outcomes and reduce the risk of ASD.

Indexed as

Lumbar VertebraePedicle ScrewsPostoperative ComplicationsSacrumAgedFemaleHumansMaleMiddle AgedRetrospective StudiesSpinal FusionTreatment OutcomeAdjacent segment degenerationLumbosacral degenerative diseaseScrew/rod mismatchSpine biomechanicsTopping-off

Identifiers

PMID40551178
PMCPMC12186315

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.