Evidence map›Paper›PMID 40549146›Full record

ArticleHeart and vessels2025

Radiation safety in catheter ablation: clinical value of real-time operator dosimetry.

Machiko Miyoshi, Kanae Hasegawa, Rikiya Maruyama, Toshiki Tateishi, Ryohei Nomura, Toshihiko Tsuji, Moe Mukai, Tetsuya Tsujikawa, Hiroyasu Uzui, Hiroshi Tada

Abstract read
In one paragraph

Article in Heart and vessels, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Machiko MiyoshiDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
Kanae HasegawaDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan. kanaeh@u-fukui.ac.jp.ORCID http://orcid.org/0000-0003-0517-0255
Rikiya MaruyamaDepartment of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
Toshiki TateishiDepartment of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
Ryohei NomuraDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
Toshihiko TsujiDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
Moe MukaiDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
Tetsuya TsujikawaDepartment of Radiology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan.
Hiroyasu UzuiDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.
Hiroshi TadaDepartment of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui, 23-3, Matsuokashimoaizuki, Eiheiji-cho, Yoshida-gun, Fukui, 910-1193, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Advances in interventional cardiology have increased procedural complexity, raising concerns about radiation exposure-especially for women operators of reproductive age, who are subject to stricter dose limits. Standard dosimeters provide only delayed cumulative data, limiting timely risk assessment. Real-time personal dosimetry offers immediate feedback, but its clinical utility during catheter ablation (CA) remains underexplored. We retrospectively analyzed 82 CA procedures performed between January and May 2024. First operators wore real-time dosimeters positioned at the waist under lead aprons. Radiation exposure and procedural characteristics were recorded and analyzed. The median operator radiation dose per procedure was 2 [1, 3] µSv, while the median patient dose was 0.163 [0.082, 0.324] Gy. A procedure-related cardiac tamponade requiring pericardiocentesis resulted in the highest operator dose (50 µSv). Higher patient BMI (≥ 25 kg/m

Indexed as

Catheter AblationOccupational ExposureRadiation ExposureRadiography, InterventionalRadiometryAdultAgedFemaleFluoroscopyHumansMaleMiddle AgedRadiation DosageRetrospective StudiesRisk AssessmentRisk FactorsCatheter ablationDosimeterRadiation doseRadiation exposureReal-time radiation monitoring

Identifiers

PMID40549146
PMCPMC12647316

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.