Evidence map›Paper›PMID 40548970›Full record

ArticleRadiologie (Heidelberg, Germany)2025

Evaluation of deep learning reconstruction in accelerated knee MRI: comparison of visual and diagnostic performance metrics.

Shenglian Wen, Yifan Xu, Guangxin Yang, Fuling Huang, Zisan Zeng

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Radiologie (Heidelberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shenglian WenDepartment of Radiology, The First Affiliated Hospital, Guangxi Medical University, No 6 Shuangyong Road, 530021, Nanning, Guangxi Zhuang Autonomous Region, China.
Yifan XuDepartment of Radiology, The First Affiliated Hospital, Guangxi Medical University, No 6 Shuangyong Road, 530021, Nanning, Guangxi Zhuang Autonomous Region, China.
Guangxin YangDepartment of Radiology, The First Affiliated Hospital, Guangxi Medical University, No 6 Shuangyong Road, 530021, Nanning, Guangxi Zhuang Autonomous Region, China.
Fuling HuangDepartment of Radiology, The First Affiliated Hospital, Guangxi Medical University, No 6 Shuangyong Road, 530021, Nanning, Guangxi Zhuang Autonomous Region, China.
Zisan ZengDepartment of Radiology, The First Affiliated Hospital, Guangxi Medical University, No 6 Shuangyong Road, 530021, Nanning, Guangxi Zhuang Autonomous Region, China. zengzisan@aliyun.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the clinical value of deep learning reconstruction (DLR) in accelerated magnetic resonance imaging (MRI) of the knee and compare its visual quality and diagnostic performance metrics with conventional fast spin-echo T2-weighted imaging with fat suppression (FSE-T2WI-FS).

methodsThis prospective study included 116 patients with knee injuries. All patients underwent both conventional FSE-T2WI-FS and DLR-accelerated FSE-T2WI-FS scans on a 1.5‑T MRI scanner. Two radiologists independently evaluated overall image quality, artifacts, and image sharpness using a 5-point Likert scale. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of lesion regions were measured. Subjective scores were compared using the Wilcoxon signed-rank test, SNR/CNR differences were analyzed via paired t tests, and inter-reader agreement was assessed using Cohen's kappa.

resultsThe accelerated sequences with DLR achieved a 36 % reduction in total scan time compared to conventional sequences (p < 0.05), shortening acquisition from 9 min 50 s to 6 min 15 s. Moreover, DLR demonstrated superior artifact suppression and enhanced quantitative image quality, with significantly higher SNR and CNR (p < 0.001). Despite these improvements, diagnostic equivalence was maintained: No significant differences were observed in overall image quality, sharpness (p > 0.05), or lesion detection rates. Inter-reader agreement was good (κ> 0.75), further validating the clinical reliability of the DLR technique.

conclusionUsing DLR-accelerated FSE-T2WI-FS reduces scan time, suppresses artifacts, and improves quantitative image quality while maintaining diagnostic accuracy comparable to conventional sequences. This technology holds promise for optimizing clinical workflows in MRI of the knee.

Indexed as

Deep LearningImage Interpretation, Computer-AssistedKnee InjuriesMagnetic Resonance ImagingAdolescentAdultAgedArtifactsFemaleHumansMaleMiddle AgedProspective StudiesSignal-To-Noise RatioArtificial IntelligenceDeep learningDenoisingFat-suppressedImage reconstruction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.