Evidence map›Paper›PMID 40545455›Full record

Trial reportZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2025

[Application of precise-guided temporary fixation assistive devices in proximal femoral nail antirotation fixation for femoral intertrochanteric fractures].

Wanming Qu, Hongbin Zhou, Xiangwei Zhang, Qinghua Xiang, Wenbin Shen, Xin Yu, Wenyao Chen, Xinzhi Li

Abstract readRandomized Controlled TrialEnglish Abstract
In one paragraph

Trial report in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wanming QuDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Hongbin ZhouDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Xiangwei ZhangDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Qinghua XiangDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Wenbin ShenDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Xin YuDepartment of Orthopedics, Yiling People's Hospital of Yichang City, Yichang Hubei, 443100, P. R. China.
Wenyao ChenDepartment of Orthopedics, Affiliated Renhe Hospital of China Three Gorges University, Yichang Hubei, 443001, P. R. China.
Xinzhi LiHubei Key Labordtory of Tumor Microenvironment and Immunotherapy, Yichang Hubei, 443002, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To investigate the feasibility and effectiveness of precise-guided temporary fixation assistive devices in assisting the main nail guide pin placement and precise temporary fixation in proximal femoral nail antirotation (PFNA) internal fixation of femoral intertrochanteric fractures. Methods: A prospective randomized controlled study was conducted to analyze the clinical data of 60 patients with femoral intertrochanteric fractures over 65 years old who met the selection criteria between January 2020 and June 2022 and were treated with PFNA internal fixation. The patients were randomly divided into the trial group (auxiliary device guided main nail guide pin placement and temporary fixation) and the control group (conventional treatment), with 30 cases in each group. There was no significant difference in baseline data such as gender, age, cause of injury, time from injury to operation, fracture side, AO/Orthopaedic Trauma Association (AO/OTA) classification, and combined medical diseases between the two groups ( Results: In the trial group, 2 temporary fixation needles were successfully placed 2-5 times, including 2 times in 13 cases (43.3%), 3 times in 8 cases (26.7%), 4 times in 7 cases (23.3%), and 5 times in 2 cases (6.7%). The operation time, times of main nail guide pin placement, intraoperative fluoroscopy frequency, and intraoperative blood loss in the trial group were significantly less than those in the control group, and the reduction quality score was significantly better than that in the control group ( Conclusion: The technique of main nail guide pin placement and temporary fixation under the guidance of auxiliary devices in PFNA internal fixation can achieve faster insertion of the main nail guide pin, accurate temporary fixation to maintain reduction, and avoid the subsequent operation space, so as to improve the effectiveness.

Indexed as

Bone NailsFracture Fixation, InternalFracture Fixation, IntramedullaryHip FracturesAgedAged, 80 and overFemaleHumansMaleOperative TimeProspective StudiesTreatment OutcomeFemoral intertrochanteric fracturemain nail guide pinprecise guidanceproximal femoral nail antirotationtemporary fixation

Identifiers

PMID40545455
PMCPMC12179243

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked