Comparison of three infusion pumps as an option for intensive care treatments in monoplace hyperbaric chambers.
Article in Diving and hyperbaric medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Hyperbaric oxygen therapy (HBOT) is used in critical care for managing certain severe conditions. However, the reliability of infusion pumps under hyperbaric conditions remains a critical concern. This study evaluated the performance of three infusion pump models - the Mindray BeneFusion VP5, Baxter Flo-Gard 6201, and Braun Infusomat Space - under hyperbaric conditions. Methods: Infusion pumps were modified to deliver flow into an environment pressurised up to 284 kPa. Accuracy of flow delivered into a pressurised monoplace chamber were tested across a range of infusion rates (1-100 mL·h⁻¹), with different absolute chamber pressures during the iso-pressure phase (243-284 kPa) and a range of different pressurisation/decompression rates (6.9-34.5 kPa·min⁻¹). Results: More than 3.6 million measurements were obtained. At iso-pressure the Mindray BeneFusion VP5 and the Baxter Flo-Gard 6201 under-performed at low infusion rates (< 20 mL·h⁻¹) and over-performed at high infusion rates (> 20 mL·h⁻¹). Both models exhibited significant under-delivery during pressurisation and over-delivery during decompression. For all conditions the Mindray BeneFusion VP5 demonstrated superior performance. The Braun Infusomat Space was unsuitable for hyperbaric use, failing to maintain performance at pressures above 90 kPa. Conclusions: The Mindray BeneFusion VP5 outperformed the Baxter Flo-Gard 6201 and Braun Infusomat Space under hyperbaric conditions, offering enhanced reliability for critical care HBOT using monoplace chambers. Clinical protocols should prioritise pumps capable of maintaining flow accuracy during pressure fluctuations. These findings inform best practices for infusion pump use in hyperbaric intensive care, addressing a critical gap in HBOT safety and efficacy.