ArticleNeurosurgical review2025
Robot-assisted versus navigated spinal fusion surgery: a comparative multicenter study on transpedicular screw placement accuracy and patient outcomes.
Article in Neurosurgical review, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Robotic-assisted versus navigation-guided spinal surgery: a meta-analysis of perioperative, clinical outcomes, and complications.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Pooled it
- Robot-assisted versus fluoroscopy-guided spinal fusion for lumbar spondylolisthesis: a GRADE-assessed meta-analysis on surgical parameters, clinical outcomes, and complications.Journal of robotic surgery · 2026Pooled it
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026Article
- Robot-assisted versus conventional posterior lumbar interbody fusion for lumbar spinal stenosis: a propensity score-matched cohort study on total and hidden blood loss.Journal of orthopaedic surgery and research · 2026Article
- Advancements in sagittal alignment parameters and management of adult spine deformities.Journal of spine surgery (Hong Kong) · 2026Review
- Response to the letter to the editor: Beyond fixation: computational and motion-integrated perspectives on pinless robot-assisted spine surgery.Asian spine journal · 2026Article
- Clinical and Radiological Outcomes of C1-C2 Fixation: 3D-Printed Template vs. Free-Hand Technique.Journal of clinical medicine · 2026Article
- Radiofrequency Ablation for Chronic Pain: Mechanistic Insights and Emerging Innovations.Cureus · 2025Review
- Global research trends in robot-assisted spinal surgery: a visualized bibliometric analysis.Journal of robotic surgery · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The transpedicular screw placement has been the gold standard for over a decade in treating degenerative diseases of the lumbo-sacral spine related to vertebral instability. The evolution of neuronavigation and robotic surgery has mitigated many perioperative complications such as mispositioning, vascular damage, and nerve structure injuries, leading to enhanced postoperative outcomes, reduced blood loss, and decreased intraoperative radiation exposure. Our study proposes a multicenter comparison between robotic surgery and neuronavigation for treating degenerative diseases of the lumbo-sacral spine. We conducted a retrospective analysis at Papardo Hospital in Messina and Garibaldi Hospital in Catania, examining a consecutive series of 76 patients treated for degenerative diseases of the lumbo-sacral spine between March 2024 and December 2024 using the Excelsius GPS Robot and neuronavigation with the O-arm. We evaluated each procedure based on age, sex, body mass index, number of involved metameres, number of screws placed, operative times, estimated blood loss (EBL), radiation exposure, type of anesthesia, accuracy (using the Gertzbein and Robbins scale), and then compared various pre- and postoperative parameters through univariate statistical analysis. Patients were randomly assigned in a 1:1 ratio using a computer-generated sequence with permuted blocks of variable size (4-6). This ensured balanced allocation and minimized selection bias. A detailed statistical plan has been included: continuous variables were assessed using Student's t-test or Mann-Whitney U test depending on distribution (Shapiro-Wilk test), while categorical variables were evaluated with Chi-square or Fisher's exact test as appropriate. 48 out of 76 patients (average age 60.47 years) underwent pedicle screw placement via robotic surgery, and 28 patients (average age 65.92 years) via neuronavigation surgery. Robotic surgery showed comparable results to neuronavigation surgery in terms of blood loss. Additionally, functional outcomes, especially those evaluated with the ODI scale and VAS scale, were similar between the two patient groups. Despite a reported mispositioning rate of 2.2% in neuronavigation surgery, no clinical impact was observed in these specific cases. The surgical procedures included both decompression (laminectomy with partial facetectomy) and fusion in all patients. Operative time was recorded as skin-to-skin time, excluding anesthesia induction and positioning. Patients with prior surgeries at the index level, complex spinal deformities (Cobb angle > 30°), or revision surgeries were excluded from this study. The included diagnoses were degenerative disc disease (RS: 56%, NS: 52%), spinal stenosis (RS: 28%, NS: 31%), spondylolisthesis (RS: 12%, NS: 14%), and traumatic pathology (RS: 4%, NS: 3%). While there was a trend towards greater precision in screw placement with robotic technology, no significant difference was observed compared to neuronavigation with the O-arm. Both technological systems used in instrumented spinal surgery appear safe and effective. However, they present a steep learning curve, and various technical aspects of these systems are continuously reassessed to improve operational efficiency and achieve these objectives.
Indexed as
Identifiers
40542927What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.