Evidence map›Paper›PMID 40538453›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2025

Exploring the impact of image restoration in simulating higher dose mammography: effects on the detectability of microcalcifications across different sizes using model observer analysis.

Renann F Brandão, Lucas E Soares, Lucas R Borges, Predrag R Bakic, Anders Tingberg, Marcelo A C Vieira

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Introduction to the JMI Special Issue on Advances in Breast Imaging.Journal of medical imaging (Bellingham, Wash.) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Renann F BrandãoUniversity of São Paulo, São Carlos School of Engineering, Department of Electrical and Computer Engineering, São Carlos, Brazil.ORCID https://orcid.org/0000-0002-8267-7095
Lucas E SoaresUniversity of São Paulo, São Carlos School of Engineering, Department of Electrical and Computer Engineering, São Carlos, Brazil.ORCID https://orcid.org/0000-0001-8772-6899
Lucas R BorgesUniversity of São Paulo, São Carlos School of Engineering, Department of Electrical and Computer Engineering, São Carlos, Brazil.ORCID https://orcid.org/0000-0003-3863-7085
Predrag R BakicLund University, Department of Translational Medicine, Faculty of Medicine, Medical Radiation Physics, Malmö, Sweden.ORCID https://orcid.org/0000-0001-7087-0915
Anders TingbergLund University, Department of Translational Medicine, Faculty of Medicine, Medical Radiation Physics, Malmö, Sweden.ORCID https://orcid.org/0000-0003-3078-0725
Marcelo A C VieiraUniversity of São Paulo, São Carlos School of Engineering, Department of Electrical and Computer Engineering, São Carlos, Brazil.ORCID https://orcid.org/0000-0002-6038-7740

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Breast cancer is one of the leading causes of cancer-related deaths among women, and digital mammography plays a key role in screening and early detection. The radiation dose on mammographic exams directly influences image quality and radiologists' performance. We evaluate the impact of an image restoration pipeline-designed to simulate higher dose acquisitions-on the detectability of microcalcifications of various sizes in mammograms acquired at different radiation doses. Approach: The restoration pipeline denoises the image using a Poisson-Gaussian noise model, combining it with the noisy image to achieve a signal-to-noise ratio comparable with an acquisition at twice the original dose. We created a database of images using a physical breast phantom at doses ranging from 50% to 200% of the standard dose. Clustered microcalcifications were computationally inserted into the phantom images. The channelized Hotelling observer was employed in a four-alternative forced-choice to evaluate the detectability of microcalcifications across different sizes and exposure levels. Results: The restoration of low-dose images acquired at Conclusions: We demonstrate the potential of an image restoration pipeline to simulate higher quality mammography images. The results indicate that reducing noise through denoising and restoration impacts the detectability of microcalcifications. This method improves image quality without hardware modifications or additional radiation exposure.

Indexed as

channelized Hotelling observerdigital mammographyimage denoisingimage restorationmicrocalcification detectionmodel observer

Identifiers

PMID40538453
PMCPMC12175087

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.