Evidence map›Paper›PMID 40537777›Full record

ArticleJournal of orthopaedic surgery and research2025

Reinforced locking screws with enhanced head and neck junction: improving biomechanical stability in opening-wedge high tibial osteotomy applications.

Kyung-Wook Nha, Hyungsuh Kim, Kyoung-Tak Kang, Jae Gyoon Kim, Hyung Jun Park

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kyung-Wook NhaDepartment of Orthopedic Surgery, Ilsanpaik Hospital, Inje University College of Medicine, Goyangsi, Republic of Korea.
Hyungsuh KimDepartment of Orthopedic Surgery, Ilsanpaik Hospital, Inje University College of Medicine, Goyangsi, Republic of Korea.
Kyoung-Tak KangSkyve R&D Lab, Seoul, Republic of Korea.
Jae Gyoon KimDepartment of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-Gu, Ansan-si, 425-707, Gyeongki-do, Republic of Korea.
Hyung Jun ParkDepartment of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-Gu, Ansan-si, 425-707, Gyeongki-do, Republic of Korea. ppakyung@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLocking plates and screws are essential in orthopedic surgeries, including opening-wedge high tibial osteotomy (OWHTO), owing to their ability to provide angular stability and support under mechanical stress. However, screw breakage at the head and neck junction remains a significant issue, compromising fixation and requiring revision surgery. This study aimed to determine whether increasing the diameter of the locking screws at the head and neck junctions enhances biomechanical stability.

methodsSixty screws, divided into two groups (n = 30 per group) -a non-reinforced group with a standard design and a reinforced group with an increased head and neck diameter- were tested. Both groups consisted of 5.0 mm locking screws, each with a length of 80 mm. Biomechanical testing, which included compression, fatigue, and torsional strength tests, was conducted to reflect clinically relevant conditions.

resultsThe reinforced screws demonstrated significantly superior biomechanical performance. In the compression test, they exhibited a higher load to failure (909.0 ± 30.4 N vs. 757.5 ± 46.2 N, p < 0.001). In the fatigue test, the reinforced screws endured more cycles before failure (70788.6 ± 6310.6 cycles vs. 23016.2 ± 5,157.9 cycles, p < 0.001) and had a greater displacement distance (3.0 ± 0.4 mm vs. 2.3 ± 0.3 mm, p = 0.001). The torsional test showed higher torque at failure for the reinforced screws (17.3 ± 0.3 Nm vs. 16.5 ± 0.4 Nm, p < 0.001), although the angular displacement differences were not statistically significant (202.0° ± 63.9° vs. 247.2° ± 64.9°, p = 0.105).

conclusionsReinforcing the head and neck junction of locking screws significantly improves their biomechanical performance. These findings suggest that structural modifications can reduce hardware failure risks in high-stress procedures such as OWHTO, enhancing implant durability and clinical outcomes.

Indexed as

Bone ScrewsOsteotomyTibiaBiomechanical PhenomenaBone PlatesHumansMaterials TestingStress, MechanicalBiomechanical stabilityHead and neck junctionOpening-wedge high tibial osteotomyReinforced locking screwsScrew breakage prevention

Identifiers

PMID40537777
PMCPMC12178043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.