Evidence map›Paper›PMID 40536610›Full record

ArticleInternational journal of computer assisted radiology and surgery2025

Super-resolution for localizing electrode grids as small, deformable objects during epilepsy surgery using augmented reality headsets.

Hizirwan S Salim, Abdullah Thabit, Sem Hoogteijling, Maryse A van 't Klooster, Theo van Walsum, Maeike Zijlmans, Mohamed Benmahdjoub

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hizirwan S SalimHigh Performance Compute & Visualization, SURF bv, Utrecht, The Netherlands. hizirwan.salim@surf.nl.ORCID http://orcid.org/0009-0007-4685-9741
Abdullah ThabitDepartment of Radiology & Nuclear Medicine, Biomedical Imaging Group Rotterdam, Erasmus MC, Rotterdam, The Netherlands.ORCID https://orcid.org/0000-0002-0505-2198
Sem HoogteijlingDepartment of Neurology and Neurosurgery, UMC Utrecht Brain Center Utrecht, Part of ERC EpiCare, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0002-4455-6700
Maryse A van 't KloosterDepartment of Neurology and Neurosurgery, UMC Utrecht Brain Center Utrecht, Part of ERC EpiCare, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0002-6594-8965
Theo van WalsumDepartment of Radiology & Nuclear Medicine, Biomedical Imaging Group Rotterdam, Erasmus MC, Rotterdam, The Netherlands.ORCID https://orcid.org/0000-0001-8257-7759
Maeike ZijlmansDepartment of Neurology and Neurosurgery, UMC Utrecht Brain Center Utrecht, Part of ERC EpiCare, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0003-1258-5678
Mohamed BenmahdjoubDepartment of Radiology & Nuclear Medicine, Biomedical Imaging Group Rotterdam, Erasmus MC, Rotterdam, The Netherlands.ORCID https://orcid.org/0000-0003-1830-2480

Funding

HORIZON EUROPE European Research Council 803880HORIZON EUROPE Framework Programme 101095387
6 · The paper itself

Abstract

purposeEpilepsy surgery is a potential curative treatment for people with focal epilepsy. Intraoperative electrocorticogram (ioECoG) recordings from the brain guide neurosurgeons during resection. Accurate localization of epileptic activity and thus the ioECoG grids is critical for successful outcomes. We aim to develop and evaluate the feasibility of a novel method for localizing small, deformable objects using augmented reality (AR) head-mounted displays (HMDs) and artificial intelligence (AI). AR HMDs combine cameras and patient overlay visualization in a compact design.

methodsWe developed an image processing method for the HoloLens 2 to localize a 64-electrode ioECoG grid even when individual electrodes are indistinguishable due to low resolution. The method combines object detection, super-resolution, and pose estimation AI models with stereo triangulation. A synthetic dataset of 90,000 images trained the super-resolution and pose estimation models. The system was tested in a controlled environment against an optical tracker as ground truth. Accuracy was evaluated at distances between 40 and 90 cm.

resultsThe system achieved sub-5 mm accuracy in localizing the ioECoG grid at distances shorter than 60 cm. At 40 cm, the accuracy remained below 2 mm, with an average standard deviation of less than 0.5 mm. At 60 cm the method processed on average 24 stereo frames per second.

conclusionThis study demonstrates the feasibility of localizing small, deformable objects like ioECoG grids using AR HMDs. While results indicate clinically acceptable accuracy, further research is needed to validate the method in clinical environments and assess its impact on surgical precision and outcomes.

Indexed as

Augmented RealityElectrocorticographyElectrodes, ImplantedEpilepsyNeurosurgical ProceduresSurgery, Computer-AssistedArtificial IntelligenceFeasibility StudiesHumansArtificial intelligenceAugmented realityComputer-assisted surgeryEpilepsy surgeryInstrument trackingIntra-operative electrocorticographyPose estimation

Identifiers

PMID40536610
PMCPMC12575507

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.