ArticleMikrochimica acta2025
Development of a ZIF-8/LIG-based electrochemical biosensor for accurate and reliable glucose monitoring in blood.
Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Recent Advances in Graphene and Its Derivatives for Electrochemical Sensing of Small Molecules: Turn the Page.Chemical record (New York, N.Y.) · 2026Review
- A ZIF-8-Based High-Performance Glucose Electrochemical Detection Platform Constructed Using a Multi-Layer Interface Optimization Strategy.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Harnessing the exceptional enzyme immobilization capabilities of metal-organic frameworks (MOFs) and the exceptional electrochemical characteristics of graphene, we designed a highly efficient and cost-effective glucose sensor utilizing zeolitic imidazolate framework-8 (ZIF-8) and laser-induced graphene (LIG) with the aid of mediator ferrocene (Fc). By incorporating a cellulose acetate (CA) film as an anti-interference layer and a polyurethane (PU) film as a diffusion-limiting layer, the sensor exhibited a wide linear detection range for glucose (0.62 mM to 20 mM) with a low detection limit of 0.16 mM (S/N = 3). Notably, it demonstrated excellent selectivity, with no interference from common biological substances. The sensor also exhibited good stability, retaining 96.38% of its initial performance after 7 days of storage. Additionally, the sensor was effectively utilized for glucose detection in whole blood, with results closely matching those obtained from a commercial blood gas analyzer (GEM5000), as evidenced by a high Pearson's correlation coefficient (r = 0.9974). This method provides a portable glucose sensor that produces results highly consistent with those obtained from large-scale testing devices in hospitals, enabling convenient and accurate blood glucose monitoring for patients.
Indexed as
Identifiers
40536583What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.