Evidence map›Paper›PMID 40534713›Full record

ArticleData in brief2025

Data-driven thermal analysis of indoor cooling for a thermoelectric radiant panel system.

Muhammad 'Amir Roslan, Farah Liana Mohd Redzuan

Abstract read
In one paragraph

Article in Data in brief, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Muhammad 'Amir RoslanMalaysia-Japan International Institute of Technology, University of Technology Malaysia (UTM), Kuala Lumpur, Malaysia.
Farah Liana Mohd RedzuanMalaysia-Japan International Institute of Technology, University of Technology Malaysia (UTM), Kuala Lumpur, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A thermal analysis of a thermoelectric radiant panel (TERP) system was conducted to evaluate its cooling effectiveness in maintaining indoor comfort within the temperature range recommended by ASHRAE Standard 55 and Malaysian Standard (MS) 1525 under tropical climate conditions. The study utilized ANSYS software, incorporating computational fluid dynamics (CFD) tools for detailed heat transfer simulations. The analysis examined the impact of outdoor temperature variations on indoor conditions and TERP system panel temperatures by considering heat transfer mechanisms, boundary conditions, and material properties to ensure accuracy. By accounting for these factors, the simulation provided a realistic representation of the thermal environment in a tropical climate. The simulation results were visualized as 3D thermal profiles, with color contours illustrating temperature distributions across the panel surface and the indoor environment. The collected data was then simplified into graph form for easier interpretation and analysis, including an evaluation of compliance with thermal comfort standards such as ASHRAE Standard 55 and MS 1525. The findings serve as a benchmark for assessing thermoelectric cooling performance in tropical buildings and offer valuable insights for optimizing thermoelectric cooling systems in similar climates. This study contributes to the development of sustainable cooling solutions and supports further research in thermoelectric cooling applications.

Indexed as

CFDCooling effectivenessTERP systemThermal analysisThermal comfortTropical climate

Identifiers

PMID40534713
PMCPMC12175229

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.