Evidence map›Paper›PMID 40526268›Full record

Article3D printing in medicine2025

A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography.

Anna Seidlová, Norbert Svoboda, Richard Voldřich, Petra Kešnerová, Roman Matějka, David Pakizer, David Školoudík, David Netuka

Abstract read
In one paragraph

Article in 3D printing in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anna SeidlováFirst Faculty of Medicine, Charles University, Katerinská 32, Prague 2, 121 08, Czech Republic.
Norbert SvobodaDepartment of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic.
Richard VoldřichDepartment of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic.
Petra KešnerováDepartment of Neurology, 2nd Faculty of Medicine, Charles University, University Hospital Motol, V Úvalu 84, Prague 5, 150 06, Czech Republic.
Roman MatějkaDepartment of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, Kladno, 27201, Czech Republic.
David PakizerCentre for Health Research, Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, Ostrava, 703 00, Czech Republic.
David ŠkoloudíkCentre for Health Research, Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, Ostrava, 703 00, Czech Republic.
David NetukaDepartment of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic. davidnetuka7@gmail.com.

Funding

Ministerstvo Zdravotnictví Ceské Republiky NU22-04-00389
6 · The paper itself

Abstract

backgroundThe use of 3D-printed hemodynamic phantom of a stenotic carotid artery has not been extensively investigated. Our study aims to address this gap by exploring the correlation between CTA and flow parameters in hemodynamic phantom.

methodsPatients with carotid stenosis were included in a prospective study. A realistic phantoms of carotid artery stenoses were 3D-printed based on CT angiography. Stenosis severity and hemodynamic flow parameters in the phantom evaluated using duplex sonography were correlated with CTA. The primary outcome was to compare the evaluation of the percentage of stenosis based on the measurement of diameter reduction and area reduction of the carotid artery among CTA, a 3D model constructed from CTA data, and ultrasound measurement of stenosis percentage within the 3D printed phantom. The secondary outcome was to determine whether the percentage of stenosis measured by ultrasound in B-mode or ultrasound-measured flow velocities (PSV, EDV) better correlates with the stenosis percentage derived from CTA and the phantom.

resultsThe study included 95 subjects (average age 71 years, 75% male) with carotid stenosis, 39% were symptomatic. Significant correlations were found between ultrasound B-Mode findings on the phantom and CTA, with the strongest correlations for area reduction (Spearman r = 0.615, p < 0.0001) and diameter reduction (Spearman r = 0.465, p < 0.0001). The most robust correlation between PSV and EDV in stenosis and the percentage of stenosis was identified between PSV in stenosis and the percentage of stenosis by diameter reduction, as evaluated through ultrasound. The Spearman correlation coefficient revealed a relatively strong correlation, with a value of r = 0.444 (p < 0.0001), and the Kendall Tau correlation coefficient also demonstrated significance, with a value of r = 0.302 (p < 0.0001).

conclusionsA significant correlation between CTA and duplex sonography measurements on the carotid phantom was demostrated, suggesting the potential utilization of the phantom in testing hemodynamic parameters of carotid stenosis.

Indexed as

3D-printed phantomCarotid stenosisCT angiographyUltrasound measurements

Identifiers

PMID40526268
PMCPMC12172251

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.