Evidence map›Paper›PMID 40526189›Full record

ArticleMedical & biological engineering & computing2025

Ligament pre-tension determines outcome in sacroiliac joint in silicon modelling.

Mark Heyland, Hendrik Schmidt, Friederike Schömig, Daven Maikath, Dominik Deppe, Matthias Pumberger, Georg N Duda, Katharina Ziegeler, Philipp Damm

Abstract read
In one paragraph

Article in Medical & biological engineering & computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Hounsfield unit threshold to predict lumbar fusion failure: a finite element study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mark HeylandJulius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany. mark.heyland@bih-charite.de.ORCID http://orcid.org/0000-0001-7474-3948
Hendrik SchmidtJulius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.
Friederike SchömigCentrum Für Muskuloskeletale Chirurgie (CMSC), Charité - Universitätsmedizin Berlin, Berlin, Germany.
Daven MaikathJulius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.
Dominik DeppeDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany.
Matthias PumbergerCentrum Für Muskuloskeletale Chirurgie (CMSC), Charité - Universitätsmedizin Berlin, Berlin, Germany.
Georg N DudaJulius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.
Katharina ZiegelerDepartment of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Berlin, Germany.
Philipp DammJulius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.

Funding

Deutsche Forschungsgemeinschaft 430577036Deutsche Forschungsgemeinschaft 439742772Deutsche Forschungsgemeinschaft 467867720German Research Foundation 427826188
6 · The paper itself

Abstract

Biomechanical analyses of the sacroiliac joint (SIJ) are limited. We hypothesize that influence of ligament pre-tension on strain and relative joint movement is morphologically sex-specific and more pronounced than effects of body weight. Finite element models were developed from CTs of a larger cohort (N = 818) for typical male (TMJ) and typical female joint (TFJ) geometries. For different loading scenarios, stresses were higher in TFJ than TMJ for same pre-tension, only considering sex-specific morphology. Loading in antero-posterior direction caused highest stresses and relative movement. Ligament pre-tension was most sensitive with mean sensitivity factor (change output [%]/change input [%]): 71.04/33.64 for translation, 43.09/4.02 for rotation, 2.11/ - 8.97 for stress for TFJ/TMJ respectively. Mean sensitivity factor of ligament stiffness was - 1.14/ - 1.06 for translation, - 0.90/ - 0.89 for rotation and 0.17/0.13 for stress, while mean sensitivity of load intensity was 1.09/1.10 for translation, 0.91/0.88 for rotation and 0.54/0.58 for stress for TFJ/TMJ respectively. Relative motion was more sensitive to parameter variations than stress. The hypothesis was confirmed: influence of ligament pre-tension on stress but especially relative joint movement of SIJ is morphologically sex-specific and larger than body weight effects. As this may play a crucial role in pain development, ligament pre-tension must be verified in situ in the future.

Indexed as

LigamentsModels, BiologicalSacroiliac JointAdultBiomechanical PhenomenaFemaleFinite Element AnalysisHumansMaleMiddle AgedStress, MechanicalTomography, X-Ray ComputedBiomechanicsFinite element model sensitivityLigament elasticitySacrumSpine

Identifiers

PMID40526189
PMCPMC12634734

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.