ArticleAnalytical chemistry2025
Metal Ion Isotope Ratio Using ESI-Orbitrap HRMS: Proof of Concept and Initial Performance Evaluation for Lead Isotopic Ratios.
Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study introduces a novel approach using an electrospray source coupled to an Orbitrap MS instrument to determine metal isotope ratios. The procedure involves forming a complex between the ion of interest and an appropriate ligand, generating gas-phase ions via electrospray ionization, selecting the complex mass by quadrupole filtering, and performing collisional fragmentation to yield free metal ions. The isotopic pattern of the free ion is then analyzed by high-resolution MS. The approach ensures high selectivity and interference-free spectra. A proof-of-concept study was conducted to determine Pb isotope ratios, focusing on identifying the factors that influence the accuracy and precision of the procedure. At this early stage, optimal accuracy was achieved even in the presence of matrix components by applying mass bias correction methods originally developed for other isotope ratio techniques; precision is comparable to that achieved by single-collector ICP-MS instrumentation. This approach may complement conventional methods that suffer from limited mass resolution and usually require extensive sample preparation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.