Evidence map›Paper›PMID 40525144›Full record

ArticleAnnals of thoracic surgery short reports2025

Minimally Invasive Implantation of an Extravascular Implantable Cardioverter-Defibrillator Device in a 2 Year Old.

Daniel A Rabin, Robert M Huibonhoa, Mark D Plunkett, Sunita J Ferns, Harma K Turbendian

Abstract readCase Reports
In one paragraph

Article in Annals of thoracic surgery short reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Daniel A RabinUniversity of Illinois College of Medicine, Peoria, Illinois.
Robert M HuibonhoaPediatric Critical Care, Department of Pediatrics, University of Illinois College of Medicine, Peoria, Illinois.
Mark D PlunkettPediatric and Congenital Cardiac Surgery, Department of Surgery, University of Illinois College of Medicine, Peoria, Illinois.
Sunita J FernsPediatric Cardiology, Department of Pediatrics, University of Illinois College of Medicine, Peoria, Illinois.
Harma K TurbendianPediatric and Congenital Cardiac Surgery, Department of Surgery, University of Illinois College of Medicine, Peoria, Illinois.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Automated implantable cardioverter defibrillator device implantation in young children is a rare procedure that typically necessitates intrapericardial lead placement. The extravascular implantable cardioverter defibrillator device can be implanted with the patient in a substernal position and with a straightforward and minimally invasive technique. The largest incision is made to accommodate the generator device. The alignment of the coils and device provides a good vector for defibrillation while permitting somatic growth. Here we describe implantation of an extravascular implantable cardioverter defibrillator in a 2-year-old child, among the youngest patients to receive this device to date.

Identifiers

PMID40525144
PMCPMC12167553

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.