ArticleACS omega2025
Development of a Mixed Solution Certified Reference Material of Vanillin Spices.
Article in ACS omega, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Simultaneous determination of vitamin A and E in infant formula using a modified QuEChERS approach coupled with ultrahigh-performance liquid chromatography-diode array detection.Food chemistry: X · 2026Article
- Certification of a novel matrix reference material for accurate measurements of PFOS and PFOA in prawn.Analytical and bioanalytical chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Well-characterized solution certified reference materials (CRMs) are necessary for the accurate determination, quality control, instrument calibration, and validation of analytical approach. Simultaneously, a mixed solution CRM of vanillin spices is in high demand because of the accurate measurement and traceability of vanillin spices in various food matrices. In this study, a mixed vanillin spices acetonitrile CRM (issued with GBWE 086557), including methylvanillin, ethylvanillin, vanillin, and coumarin, has been developed using the gravimetric method by the National Institute of Metrology, China. Methylvanillin, ethylvanillin, and vanillin showed poor stability in methanol. The acetalization of the aldehyde group of vanillin was the major step during the degradation process, as elucidated by ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS), and exposure to high temperature and light irradiation accelerated the degradation dramatically, whereas the acetonitrile CRMs held sufficient homogeneity, and they were stored stable at 4 °C over 9 months or 50 °C for 7 days. Typically, the certified values for methylvanillin, ethylvanillin, vanillin, and coumarin in CRM were 10.1 ± 0.2, 10.2 ± 0.2, 10.0 ± 0.3, and 10.0 ± 0.2 μg/mL (
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.