Evidence map›Paper›PMID 40521120›Full record

ArticleMethodsX2025

Case report: A novel technique of robotic low-tension hiatal hernia repair using mediastinoplication.

Carlos Eduardo Domene, Carlos Augusto Scussel Madalosso, Victor Ramos Mussa Dib, Paulo Reis Rizzo Esselin de Melo, André Valente Santana, William Carlos Giglio Mira Neto, Paula Volpe

Abstract read
In one paragraph

Article in MethodsX, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Carlos Eduardo DomeneIntegrated Center for Advanced Medicine (CIMAMED), 74 Dona Adma Jafet Street, Suite 162, Bela Vista, São Paulo - SP, 01308-050, Brazil.
Carlos Augusto Scussel MadalossoGastrobese Clinic, 1953 Uruguai St., 8th floor, 99010-111, Passo Fundo - RS, Brazil.
Victor Ramos Mussa DibVictor Dib Institute, 1444 Álvaro Botelho Maia Ave, 69020-210, Manaus - AM, Brazil.
Paulo Reis Rizzo Esselin de MeloPaulo Reis Institute, Trade Center Building Condominium, 2nd Floor, Suite 202, 250 Street 10, Block B-6, Lot 5/9, Setor Oeste, Goiânia - GO, 74120-020, Brazil.
André Valente SantanaDepartment of Surgery, Escola Paulista de Medicina, Federal University of São Paulo, 740 Botucatu Street, Vila Clementino, São Paulo - SP, 04023-062, Brazil.
William Carlos Giglio Mira NetoRede D´Or Hospital São Luiz Itaim, 95 Dr. Alceu de Campos Rodrigues Street, Vila Nova Conceição, São Paulo - SP, 04544-000, Brazil.
Paula VolpeIntegrated Center for Advanced Medicine (CIMAMED), 74 Dona Adma Jafet Street, Suite 162, Bela Vista, São Paulo - SP, 01308-050, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surgery for giant hiatal hernias presents significant challenges, with laparoscopic surgery widely regarded as the gold standard. This approach typically involves complete resection of the hernia sac, thorough esophageal mobilization, tension-free closure of the diaphragmatic crura, and proper fundoplication. Despite various strategies to reduce recurrence, such as mesh reinforcement, there is no consensus on their superiority over traditional methods. Robotic surgery introduces greater precision, particularly in complex cases involving large hernias (grades III and IV). It facilitates safer dissections and more effective esophageal mobilization, challenging the concept of a short esophagus. A novel technique, mediastinoplication, addresses the positive abdominal-thoracic pressure gradient, a key factor in hernia recurrence. By reducing mediastinal dead space and approximating mediastinal structures, this technique aims to minimize tension on the crura and reduce recurrence, seroma, hematoma, and abscess. While further validation of mediastinoplication's long-term efficacy is needed, it adheres to fundamental surgical principles and offers a promising solution to high recurrence rates. Future studies are essential to establish its role in standard practice.•Introduces robotic mediastinoplication as a novel technique.•Robotic suturing increases the feasibility of suturing mediastinal structures that are inaccessible by traditional laparoscopic methods.•Mediastinoplication reduces tension, allowing a low-tension hiatal repair.

Indexed as

Abdominal-thoracic pressure gradientDiaphragmatic cruraGiant hiatal herniaInnovative surgical techniqueLow-tension repairMediastinal dissectionMediastinoplicationMinimally invasive proceduresRecurrent hiatal herniaRobotic Low-Tension Hiatal Hernia Repair Using MediastinoplicationRobotic surgery

Identifiers

PMID40521120
PMCPMC12164190

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.