Evidence map›Paper›PMID 40521007›Full record

ArticleDrug design, development and therapy2025

Development and Validation of a UPLC-MS/MS Detection Method of Baricitinib for Therapeutic Drug Monitoring in COVID-19 Patients.

Ruanjuan Zhan, Yuxin Shen, Haoxin Fu, Hualu Wu, Xiaohai Chen, Yige Yu, Ren-Ai Xu

Abstract readValidation Study
In one paragraph

Article in Drug design, development and therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ruanjuan Zhan *Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.ORCID 0000-0002-5046-9806
Yuxin Shen *Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Haoxin FuDepartment of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Hualu WuDepartment of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Xiaohai ChenDepartment of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.ORCID 0009-0009-5017-5515
Yige YuDepartment of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Ren-Ai XuDepartment of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Baricitinib is widely used as a selective Janus kinase (JAK) inhibitor for the treatment of immune-mediated inflammatory diseases in clinic. It is now successfully applied in reducing inflammation and suppressing COVID-19-associated immune dysregulation. As knowledge of the appropriate plasma level of baricitinib in COVID-19 patients is deficient, the measurement of the level of baricitinib in plasma during treatment is necessary and important. Purpose: The aim of this study was to establish a bioanalytical method to detect the concentration of baricitinib in COVID-19 patients' plasma by ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). Methods: The preparation process of the injected sample was to spike 100 μL of plasma and 10 μL of internal standard (IS, upadacitinib) working solution, then add 1:3 of acetonitrile to obtain the supernatant. The intra-day and inter-day precision and accuracy, matrix effect, recovery, and stability of the established methodology were all required. Results: The method was established to determine the plasma levels in 22 COVID-19 patients. After taking 2 mg/day or 4 mg/day of baricitinib, the mean plasma concentrations of the patients were 15.36 ng/mL and 12.64 ng/mL, respectively. Conclusion: This novel UPLC-MS/MS method enables rapid and accurate determination of baricitinib concentrations in human plasma, which is suitable for the therapeutic drug monitoring (TDM) of baricitinib.

Indexed as

AzetidinesCOVID-19 Drug TreatmentDrug MonitoringPurinesPyrazolesSulfonamidesTandem Mass SpectrometryChromatography, High Pressure LiquidCOVID-19FemaleHumansLiquid Chromatography-Mass SpectrometryMaleMiddle AgedReproducibility of ResultsSARS-CoV-2AzetidinesbaricitinibPurinesPyrazolesSulfonamidesbaricitinibCOVID-19drug monitoringUPLC-MS/MS

Identifiers

PMID40521007
PMCPMC12164873

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.