Evidence map›Paper›PMID 40520220›Full record

ArticleFrontiers in digital health2025

Continuous monitoring of critically ill patients using photoplethysmography-the road to a less invasive ICU monitoring.

João Rosinhas, Rui Malheiro, João Tiago Pimenta, Ricardo Sá, Francisco Serdoura, José-Artur Paiva

Abstract read
In one paragraph

Article in Frontiers in digital health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

João RosinhasServiço de Medicina Intensiva, Unidade Local de Saúde São João, Porto, Portugal.
Rui Malheiro4LifeLAB, Laboratório Colaborativo, Porto, Portugal.
João Tiago Pimenta4LifeLAB, Laboratório Colaborativo, Porto, Portugal.
Ricardo Sá4LifeLAB, Laboratório Colaborativo, Porto, Portugal.
Francisco Serdoura4LifeLAB, Laboratório Colaborativo, Porto, Portugal.
José-Artur PaivaServiço de Medicina Intensiva, Unidade Local de Saúde São João, Porto, Portugal.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Intensive Care Medicine is based on continuous timely monitoring of physiological variables to guide modulation of therapy. This monitoring is often invasive, but there is a trend for the adoption of non-invasive devices, already largely used in wards and homecare, to reduce risk of device-associated side effects. The aim of this study was to assess the accuracy of a non-invasive equipment (Corsano Cardiowatch 287-2B) in the assessment of blood pressure, heart rate, temperature and oxygen saturation in critically ill patients admitted to the ICU. Method: This prospective cohort study developed in an adult ICU admitting patients for level 3 and 2 of care compared the Corsano Cardiowatch 287-2B with the ICU standard monitoring, namely continuous electrocardiogram, invasive arterial blood pressure through arterial catheter, pulse oximeter and central thermometer. Concordance was assessed using the Bland-Altman test. Results: Nineteen patients were included in the study. The number of time-points included for comparison between the two monitoring strategies were more than 50,000 in pulse and heart rate, around 40,000 in oxygen saturation and body temperature and 1,200 in systolic and diastolic blood pressure. Bias for heart rate and pulse were -1.73 and -0.77, respectively. The limits of agreement were between -14.90 and 11.33, for heart rate, and -14.25 and 12.71, for pulse. Small biases were also estimated for oxygen saturation (0.21), with limits of agreement between -6.97 and 7.39, and body temperature (0.58), with limits between -1.12 and 2.47. Concordance was low for diastolic and systolic blood pressure, with bias of 5.18 and -11.27, respectively. Conclusions: Corsano Cardiowatch 287-2B reaches good levels of concordance compared to traditional ICU monitoring for heart and pulse rates and may be a valuable solution for their less invasive monitoring, with promising results for future operationalization for oxygen saturation and body temperature. Concordance is low for blood pressure, meaning the device is currently unsuitable for use with that purpose.

Indexed as

ICUmonitoringnon-invasivepulsetele-ICU

Identifiers

PMID40520220
PMCPMC12162652

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.