Evidence map›Paper›PMID 40519339›Full record

ArticleJournal of orthopaedics2025

Laminoplasty plate design is an independent risk factor for facet joint violation.

Alejandro Perez-Albela, Ishan Shah, Tucker Callanan, Timothy Jeng, Sonia Sheth, Bryce Basques

Abstract read
In one paragraph

Article in Journal of orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alejandro Perez-AlbelaDepartment of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA.
Ishan ShahThe Warren Alpert Medical School, Brown University, Providence, RI, USA.
Tucker CallananDepartment of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA.
Timothy JengThe Warren Alpert Medical School, Brown University, Providence, RI, USA.
Sonia ShethThe Warren Alpert Medical School, Brown University, Providence, RI, USA.
Bryce BasquesDepartment of Orthopedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Cervical laminoplasty is a motion-preserving surgical technique for cervical myelopathy. Laminoplasty plates stabilize the spinal canal, often using different plate designs that define screw trajectory. Although it is recognized that screws penetrating facet joints can lead to worse postoperative pain scores and outcomes, limited research has examined the outcomes associated with the different orientations of laminoplasty plates, which may contribute to screw-related complications such as facet joint violation (FJV). This study evaluates the impact of laminoplasty plate design and screw orientation on FJV incidence, operative time, and clinical outcomes. Methods: This is a retrospective review of 105 patients receiving unilateral open-door cervical laminoplasty for myelopathy or myeloradiculopathy. Data was collected from 2017 to 2023 at a single institution and procedures were performed by one of six fellowship-trained spine surgeons. Patients with ≥1-year radiographic and clinical follow-up were included. Radiographic parameters (C2-7 Cobb angle, T1 slope, Torg-Pavlov ratio, and C2-7 SVA) were assessed preoperatively, postoperatively, and at 1 year. Groups were separated by the plate design, with one group having horizontal oriented lateral screws and the other having vertical. FJV was defined as screw penetration ≥2 mm beyond the facet cortex. Results: A total of 105 patients were included (65 horizontal, 40 vertical). Groups were similar in age, BMI, sex, smoking status, diabetes, and CCI (all p > 0.05). Preoperative cervical sagittal parameters were also comparable. Postoperatively, the vertical group had significantly greater loss of C2-7 lordosis (3.22° ± 10.37) compared to the horizontal group (-1.39° ± 11.76; p = 0.03), with this difference persisting at final follow-up (1.38° ± 12.27 vs. -5.21° ± 12.07; p = 0.01). Facet joint violation occurred more frequently in the vertical group (60.0 % vs. 32.3), with multivariate analysis identifying vertical plate orientation as an independent risk factor (OR 11.7, p = 0.01). Vertical plate orientation was also independently associated with increased operative time (+29.5 min, p = 0.02). Conclusion: Vertical laminoplasty plate orientation was associated with increased FJV risk and longer operative time, as well as greater loss of lordosis within a year postoperatively, though it did not affect pain scores. Further research is needed to evaluate the long-term implications of FJV on patient outcomes.

Indexed as

Cervical laminoplastyFacet joint violationLaminoplasty platesPostoperative outcomesRadiographic outcomesScrew orientation

Identifiers

PMID40519339
PMCPMC12162463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.