Impact of reduced interval from simulation CT to treatment delivery on dosimetric and positioning accuracy for total marrow lymph-node irradiation.
Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04976205 (Artificial Intelligence Algorithms to Automate the Total Marrow), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Artificial Intelligence Algorithms to Automate the Total Marrow (Lymph-node) Irradiation by VMAT Optimization Using WB-CT/MRI and Synthetic WB-CT - The AuToMI Project
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeTotal marrow (lymph-node) irradiation (TMI/TMLI) is designed to minimize toxicities of conventional total body irradiation in hematopoietic stem cell transplant conditioning. Planning typically relies on a computed tomography (CT) scan acquired many days before treatment (e.g. 15 days; CT-15) to allow time for plan optimization. However, anatomical changes during this interval, influenced by patient condition and concurrent therapies, can compromise dosimetric accuracy. This study evaluates the impact of shortening the CT-to-treatment timeframe to 4 days (CT-4) on dosimetric and positioning accuracy in TMI/TMLI.
methodsEighteen patients were enrolled in this prospective study (ClinicalTrials.gov: NCT04976205). Treatment plans, optimized with a multi-isocenter volumetric modulated arc therapy on CT-15, were recalculated on CT‑4 to assess changes in planning target volume (PTV) dose coverage (PTV_D98%). Image matching quality between CT-15/CT‑4 and cone-beam CT acquisitions was assessed with a scale of 1 to 5. Wilcoxon signed-rank test with significance set at p < 0.05 was considered.
resultsA significant reduction in median PTV_D98% was found between CT-15 (98.0%, minimum/maximum [98.0, 98.0]%) and CT‑4 (92.2%, [62.9, 98.9]%). Image matching quality improved in 72% of patients using CT‑4 compared to CT-15. In 11% of cases, relevant discrepancies required re-optimization using CT‑4.
conclusionsThese findings underscore the benefits of a shorter CT-to-treatment timeframe for improving dosimetric and positioning accuracy in TMI/TMLI. Automated planning tools may further enhance TMI/TMLI workflows, particularly for patients undergoing intensive conditioning protocols.