Evidence map›Paper›PMID 40512410›Full record

ArticleEJNMMI physics2025

IDAC-Dose 2.2, an internal dosimetry software for diagnostic nuclear medicine based on the latest ICRP adult and paediatric reference computational phantoms.

Martin Andersson, Keith Eckerman, Sören Mattsson

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Martin AnderssonDepartment of Radiation Physics, Sahlgrenska Cancer Center, Medical Radiation Physics, Department of Translational Medicine, University of Gothenburg, Lund University, Skåne University Hospital, Malmö, Malmö, SE-205 02, Sweden. martin.andersson.2@gu.se.ORCID http://orcid.org/0000-0003-1275-5710
Keith EckermanCenter for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, TN, USA. eckermank@bellsouth.net.
Sören MattssonMedical Radiation Physics, Department of Translational Medicine, Lund University, Skåne University Hospital, Malmö, Malmö, SE-205 02, Sweden. soren.mattsson@med.lu.se.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor patients investigated with radiopharmaceuticals, it is important to be able to perform valid calculations of the absorbed dose in organs and tissues. An internal dosimetry computer program, IDAC-Dose2.1, has been updated to be based on the ICRP specific absorbed fractions and computational framework of internal dose assessment for 12 adult and paediatric reference individuals given in ICRP Publication 133 and 155. The updated dosimetry software intended for nuclear medicine is named IDAC-Dose2.2. The calculations are based on radionuclide decay scheme of ICRP Publication 107. Biokinetic models can be based on up to 83 different source regions irradiating 48 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry software, DCAL ver. 2022, that employs the same computational framework and is used for occupational and environmental intakes of radionuclides. IDAC-Dose2.2 calculates absorbed doses to the 2 adult and 10 paediatric,15-yrs, 10-yrs, 5-yrs, 1-yr, 100 days (infant) and 0 day (new-born), sex specific ICRP reference phantoms. It has an additional sub-module which can interpolate the calculated absorbed dose and effective dose to an arbitrary age between 0 and 20 years (20 years = adult) or an arbitrary weight of 3.5-73 kg for male and 3.5-64 kg for female instead of only using the 6 fixed phantoms ages.

resultsIDAC-Dose2.2 was applied on three frequently used radiopharmaceuticals: intravenously administered 2-[

conclusionsThe internal dosimetry program IDAC-Dose was updated to include all 12 specific sets of absorbed fractions of the ICRP adult and paediatric reference phantoms and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for preadults in diagnostic nuclear medicine. The sub-module for age or weight interpolation of absorbed doses follows the ICRP computational framework used for members of the public. IDAC-Dose2.2 will used by the ICRP for absorbed and effective dose calculations in diagnostic nuclear medicine. The results from other software, which uses the same primer data (e.g. ICRP SAF values or decay data) could deviate from those of IDAC-Dose 2.2 and published ICRP dose values if the software do not follow the ICRP computational framework for internal dosimetry. IDAC-Dose2.2 is a free software for research and available at http://www.idac-dose.org . The online version can be operated directly through a web browser and the standalone version is an executable file, which is downloaded and installed directly on the local computer.

Indexed as

DCALDiagnostic nuclear medicineEffective doseICRPIDACInternal dosimetryRadiopharmaceuticals

Identifiers

PMID40512410
PMCPMC12165913

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked