Evidence map›Paper›PMID 40512377›Full record

ReviewNeuroradiology2025

Distal anchoring techniques for reducing intra-aneurysmal (around-the-world) microcatheter loop prior to stent deployment across large wide-necked aneurysms- an educational review.

Kautilya R Patel, Alejandro M Spiotta, Nicholas Borg, William E Thorell, Daniel L Surdell, Mithun G Sattur

Abstract readReview
PubMed Publisher
In one paragraph

Review in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kautilya R PatelDepartment of Neurosurgery, University of Nebraska Medical Center, Omaha, United States.ORCID http://orcid.org/0000-0002-2900-7818
Alejandro M SpiottaDepartment of Neurosurgery, Medical University of South Carolina, Charleston, United States.
Nicholas BorgDepartment of Neurosurgery, University of Nebraska Medical Center, Omaha, United States.
William E ThorellDepartment of Neurosurgery, University of Nebraska Medical Center, Omaha, United States.
Daniel L SurdellDepartment of Neurosurgery, University of Nebraska Medical Center, Omaha, United States.
Mithun G SatturDepartment of Neurosurgery, University of Nebraska Medical Center, Omaha, United States. msattur@unmc.edu.ORCID http://orcid.org/0000-0002-2404-3780

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEstablishing parent artery access for stent placement across large wide-necked aneurysms can be challenging. 'Around-the-world' technique, forming an intra-aneurysm loop with some form of distal anchoring, has been described in several reports. This comprehensive educational review summarizes the different variations of this technique, with their relative advantages and disadvantages. The review is supported with a technical case description of balloon-anchoring technique, one of the already described techniques in a patient with proximal posterior cerebral artery aneurysm.

methodsA comprehensive literature search was conducted to identify studies describing intra-aneurysmal looping with different distal anchoring techniques. A narrative synthesis of the data obtained from the identified studies was performed.

resultsThirteen retrospective studies with 51 patients and the patient in the current report were included in the review. Different techniques described include balloon anchoring, stent anchoring, coil anchoring, vacuum anchoring, rapid pull-back and wire anchor loop traction techniques. Largest dimension of the aneurysms ranged from 12.3 mm to 29 mm with a mean of 19.9 mm (8 studies, 44 aneurysms). Neck size ranged from 5.2 mm to 15 mm with a mean of 10.4 mm (5 studies, 10 aneurysms). Aneurysms were unruptured in all 6 studies reporting the rupture status. Majority of the studies reported good outcomes with only two patients (3.9%) developing complications (intraparenchymal hematoma- 1, caroticocavernous fistula- 1). The choice of technique in a given case would depend on operator experience, expertise and in some instances, local infrastructure. This study is limited by a potential for publication bias and retrospective nature of the included studies.

conclusionIntra-aneurysmal looping with different technical variations for distal anchoring in the parent artery is an effective technical maneuver for deploying a stent across large wide-necked aneurysms. Comparative efficacy of different techniques and high level recommendations are difficult to provide given the relative infrequency of the situation, limited case numbers published and inconsistent reporting, including under-reporting.

Indexed as

Embolization, TherapeuticEndovascular ProceduresIntracranial AneurysmStentsHumansAround-the-worldGiant aneurysmIntra-aneurysm loopPosterior cerebral arteryPosterior communicating arteryWide-necked aneurysm

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.