Evidence map›Paper›PMID 40511365›Full record

ArticleIEEE transactions on medical robotics and bionics2023

Simultaneous Estimation of Hand Configurations and Finger Joint Angles Using Forearm Ultrasound.

Keshav Bimbraw, Christopher J Nycz, Matthew Schueler, Ziming Zhang, Haichong K Zhang

Abstract read
In one paragraph

Article in IEEE transactions on medical robotics and bionics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Keshav BimbrawDepartment of Robotics Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.ORCID 0000-0003-3735-7700
Christopher J NyczPracticePoint, Worcester Polytechnic Institute, Worcester, MA 01605.ORCID 0000-0002-3753-786X
Matthew SchuelerDepartment of Robotics Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Ziming ZhangVision, Intelligence, and System Laboratory, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Haichong K ZhangMedical FUSION Laboratory, Worcester Polytechnic Institute, Worcester, MA 01609 USA.ORCID 0000-0002-1314-8456

Funding

Robotic Lung Ultrasound for Triage of COVID-19 Patients in a Resource-Limited EnvironmentDP5OD028162 · OD · WORCESTER POLYTECHNIC INSTITUTE · PI ZHANG, HAICHONG · 2019 to 2023
$2.3M
NIH HHS DP5 OD028162
6 · The paper itself

Abstract

With the advancement in computing and robotics, it is necessary to develop fluent and intuitive methods for interacting with digital systems, augmented/virtual reality (AR/VR) interfaces, and physical robotic systems. Hand motion recognition is widely used to enable these interactions. Hand configuration classification and metacarpophalangeal (MCP) joint angle detection is important for a comprehensive reconstruction of hand motion. Surface electromyography (sEMG) and other technologies have been used for the detection of hand motions. Forearm ultrasound images provide a musculoskeletal visualization that can be used to understand hand motion. Recent work has shown that these ultrasound images can be classified using machine learning to estimate discrete hand configurations. Estimating both hand configuration and MCP joint angles based on forearm ultrasound has not been addressed in the literature. In this paper, we propose a convolutional neural network (CNN) based deep learning pipeline for predicting the MCP joint angles. The results for the hand configuration classification were compared by using different machine learning algorithms. Support vector classifier with different kernels, multi-layer perceptron, and the proposed CNN have been used to classify the ultrasound images into 11 hand configurations based on activities of daily living. Forearm ultrasound images were acquired from 6 subjects instructed to move their hands according to predefined hand configurations. Motion capture data was acquired to get the finger angles corresponding to the hand movements at different speeds (0.5 Hz, 1 Hz, & 2 Hz) for the index, middle, ring, and pinky fingers. Average classification accuracy of 82.7 ± 9.7% for the proposed CNN and over 80% for SVC for different kernels was observed on a subset of the dataset. An average RMSE of 7.35°±1.3° was obtained between the predicted and the true MCP joint angles. A low latency (6.25 - 9.1 Hz) pipeline has been proposed for estimating both MCP joint angles and hand configuration aimed at real-time control of human-machine interfaces.

Indexed as

AI-enabled roboticsand facial expressionsdesign and development of robots for human-robot interactiongesturehuman-machine interfaces and robotics applicationsnew technologies and methodologies in medical roboticspostureuser-centered design and applicationswearable roboticswearable sensor systems

Identifiers

PMID40511365
PMCPMC12162105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.