Evidence map›Paper›PMID 40506767›Full record

ArticleEuropean journal of medical research2025

Effect of tibial rotational alignment and posterior slope on joint biomechanics in posterior-stabilized total knee arthroplasty: a finite element study.

Long Shao, Xiangdong Wu, Chaohua Fang, Hongli Zhu, Kun Tao, Shicheng Wang

Abstract read
In one paragraph

Article in European journal of medical research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Long ShaoJoint and Sports Medicine Center, Ningbo No.6 Hospital, 1059 Zhongshan East Road, Ningbo, 315040, Zhejiang, China.
Xiangdong WuDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Fourth Clinical College of Peking University, National Center for Orthopaedics, Beijing, 100035, China.
Chaohua FangJoint and Sports Medicine Center, Ningbo No.6 Hospital, 1059 Zhongshan East Road, Ningbo, 315040, Zhejiang, China.
Hongli ZhuTechnology Department, Chongqing Optical Machinery Research Institute, Chongqing, 401122, China.
Kun TaoJoint and Sports Medicine Center, Ningbo No.6 Hospital, 1059 Zhongshan East Road, Ningbo, 315040, Zhejiang, China.
Shicheng WangJoint and Sports Medicine Center, Ningbo No.6 Hospital, 1059 Zhongshan East Road, Ningbo, 315040, Zhejiang, China. woson004@163.com.

Funding

Zhejiang Medical Health Science and Technology plan 2022RC068
6 · The paper itself

Abstract

backgroundThis study aims to clarify the combined influence of the tibial rotational alignment and posterior slope on knee joint biomechanics after posterior-stabilized total knee arthroplasty using a computer simulation.

methodsComputer tomographic and magnetic resonance imaging scan of a healthy volunteer were used to reconstruct a detailed 3D geometrical model. A virtual surgery was performed to generate a resection plane with different posterior slopes and rotational alignment on the proximal tibia. The internal, neutral and external rotation, combined with a posterior slope of 0, 3, 5, and 7 degrees were simulated for both standing and bending position. The differences in contact pressure, area and stress of polyethene liner and the tensile stress of the soft tissue were compared.

resultsThe contact area on the polyethylene liner decreased with increasing posterior slope in a standing position while the opposite trend was found in a bending position. In a bending position, internal rotation of tibial component resulted in smaller contact areas than neutral or external rotation. A posterior slope of 0° combined with neutral rotation in a standing position showed the smallest pressure on the liner with biggest contact area. The distribution of von Mises stress was more uniform with 0° and 3° than 5° and 7° posterior tibial slope for both standing and bending position. The stress increased with increasing posterior slope in both standing and bending position, ranging from 8.77 MPa to 79.39 MPa. The ligament and muscle tensile stress increased with increasing posterior slope in both standing and bending position. In addition, the neutral rotation showed lower maximum stress compared with other rotational alignment in a standing position.

conclusionsAn increased posterior slope increases the contact pressure and stress of the polyethene liner and the ligament tensile stress. A neutral rotation combined with a posterior slope of less than 3° showed superior biomechanical results in posterior-stabilized TKA.

Indexed as

Arthroplasty, Replacement, KneeKnee JointTibiaBiomechanical PhenomenaComputer SimulationFinite Element AnalysisHumansKnee ProsthesisMaleRange of Motion, ArticularRotationTomography, X-Ray ComputedBiomechanical analysisComputational simulationPosterior slopeRotational alignmentTibial componentTotal knee arthroplasty

Identifiers

PMID40506767
PMCPMC12160434

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.