Evidence map›Paper›PMID 40506459›Full record

ArticleMicrosystems & nanoengineering2025

A 70 MPa silicon resonant pressure microsensor with resonators supported by micro beams based on volume compressed sensing.

Zongze Yu, Pan Qian, Yulan Lu, Bo Xie, Deyong Chen, Junbo Wang, Jian Chen

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zongze YuState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.
Pan QianState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.
Yulan LuState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China. luyl@aircas.ac.cn.ORCID http://orcid.org/0000-0003-3826-5998
Bo XieState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.
Deyong ChenState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.
Junbo WangState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.
Jian ChenState Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China.ORCID http://orcid.org/0000-0003-4612-3279

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Meeting the growing demands for accuracy, resolution and response time of high-pressure microsensors applicated in ocean science and petroleum industry, this paper developed a silicon resonant high pressure microsensor based on volume compressed sensing with dual resonators supported by micro beams. In operation, the frequency of resonators shifts while the volume of microsensor compressed under high pressure. A couple of micro beams were introduced to support resonators and protect resonators from buckling in high pressure. At the meanwhile, the theoretical model of micro beams was established. Based on the expression between geometric parameters of micro beams and pressure sensitivity of resonators, the micro beams of the two resonators were modified that results in different pressure sensitivities of two resonators, which effectively performed temperature self-compensation. An eutectic bonding is adopted for wafer vacuum packaged. Dealing with potentially complex hydraulic measurement, the microsensors were surrounded by silicone oil and sealed with a corrugated diaphragm and a base. The pressure sensitivities of fabricated microsensors were quantified as 0.003 kHz/MPa ( ~ 30 ppm/MPa) of Resonator I and -0.118 kHz/MPa (~-1311 ppm/MPa) of Resonator II under 20 °C, which match with theoretical analysis. Finally, the accuracy of this microsensors is better than 0.01% FS with temperature self-compensation under the pressure range of 0.1~70 MPa from -10 °C to 50 °C, along with a response time better than 10 ms and a resolution of 100 Pa. This paper provided an effective structure of micro beams for resonant high-pressure microsensors combined with volume compressed sensing, derived the quantitative relationship between key structural parameters and sensitivity, and performed a possibility of high accuracy and high resolution measurements of a much wider pressure range.

Identifiers

PMID40506459
PMCPMC12162831

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.