Evidence map›Paper›PMID 40504135›Full record

ArticleJournal of applied clinical medical physics2025

Producing high quality cranial SRS plans with 4Pi planning technique in a commercial clinical solution.

Ganesh Narayanasamy, Nishan Shrestha, Milan Bimali, Fen Xia, Zhong Su

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ganesh NarayanasamyDepartment of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.ORCID https://orcid.org/0000-0002-7608-0612
Nishan ShresthaDepartment of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.ORCID https://orcid.org/0000-0001-9802-3806
Milan BimaliDepartment of BioStatistics, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
Fen XiaDepartment of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
Zhong SuDepartment of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo generate high-quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical "status quo" plans.

methodsEighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams were randomly selected. This cohort was replanned in Brainlab Elements Cranial SRS using an automatic 4Pi trajectory optimization technique ("Elements 4Pi"). "Elements ArcMatch" plans were also created, which utilized the identical arc geometry as the clinical plans in Eclipse, that is, used identical table angles, gantry start and stop angles, and collimator angles to isolate the inherent differences between the two treatment planning systems. SRS plan evaluation metrics included the Inverse Paddick conformity index (IPCI), gradient index (GI), max doses to the brainstem and ipsilateral cochlea, and number of monitor units (MUs). Pairwise comparisons between Eclipse and Elements 4Pi plans were performed using Wilcoxon signed rank test. For three-way comparisons with Elements-ArcMatch plans, the difference in distribution of SRS metrics was assessed first based on Friedman's test, followed by pairwise comparison if the findings from Friedman's test met statistical significance. A two-sided p-value of 0.05 was used to determine statistical significance.

resultsWhile both Elements 4Pi and Elements ArcMatch plans had significantly lower GI, MU, and max doses to the brainstem and ipsilateral cochlea compared to Eclipse plans (p-values < 0.05), Elements 4Pi also had significantly lower IPCI values.

conclusionThe automation in Brainlab Elements Cranial SRS outperformed manual expert planning and produced collision-free and clinically deliverable plans for single targets with significantly better dose conformality, dose gradient, and lower dose to normal organs while using lower MUs compared to clinically delivered Eclipse plans.

Indexed as

Brain NeoplasmsNeuroma, AcousticRadiosurgeryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedAlgorithmsHumansOrgans at RiskRadiotherapy Dosage4Pi4Pi SRSacoustic neuromabrainlabelementselements cranial SRSelements image fusionSRStrajectory optimizationvestibular schwannoma

Identifiers

PMID40504135
PMCPMC12256574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.