ArticleTechnical innovations & patient support in radiation oncology2025
Evaluation of dose delivery accuracy of the lung with the respiratory technique of the Radixact Synchrony real-time tumor tracking system.
Article in Technical innovations & patient support in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Retrospective log-based quality assurance of real-time MLC adaptation on a helical tomotherapy platform.Journal of applied clinical medical physics · 2026Article
- Effect of tumor size on motion tracking and dosimetric accuracy using Radixact Synchrony.Journal of radiation research · 2026Article
- Engineering dosimetric excellence in total body irradiation: Tomotherapy-driven protocols for precision and reproducibility.Precision radiation oncology · 2026Article
- Markerless tumor tracking for lung SBRT with the Radixact Synchrony system: Initial experience and short-term clinical outcomes.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This study aims to evaluate the dosimetric accuracy of the Lung with Respiratory (LWR) technique in the Radixact Synchrony real-time tumor tracking system using data from actual patients undergoing lung SBRT. Material and methods: This retrospective study included 20 patients treated with the Synchrony LWR technique for primary lung cancer or lung metastases. Mid-ventilation breath-hold CT and 4DCT images were acquired for treatment planning and tumor motion evaluation. Gamma analysis was performed using the PTW 1500 detector. Three verification plans were generated for each patient: one for gamma analysis without motion (GAWoM), one for point dose measurement with motion (PDWM), and one for gamma analysis with motion (GAWM). Patient specific respiratory motion was simulated using a CIRS motion platform. The relationship between respiratory patterns, treatment plan parameters, and the dose delivery accuracy of the Synchrony system was evaluated using correlation analysis. Results: The PDWM results demonstrated a strong agreement between the planned and measured doses, with a maximum difference of less than 2%. The gamma passing rates of 3D dose measurements for all patients' Synchrony plans were found to be within the clinically acceptable level. While GAWM results were slightly lower than GAWoM results, correlation analysis revealed a strong positive relationship between the two. A moderate negative correlation was observed between the modulation factor and GAWM, similar to GAWoM. Additionally, a strong negative correlation was observed between beam-on time and both GAWoM and GAWM. Furthermore, no significant correlation was found between GAWM and respiratory pattern-related variables, including superior-inferior and lateral motion amplitude or respiratory rate per minute. Conclusion: The results of the correlation analyses indicate that the dose delivery accuracy of the Synchrony LWR technique is comparable to that of static target irradiation, independent of the patient's respiratory pattern or the planning parameters used.