Evidence map›Paper›PMID 40498241›Full record

ArticleInternational journal of computer assisted radiology and surgery2025

Enhancing generalization in zero-shot multi-label endoscopic instrument classification.

Raphaela Maerkl, Tobias Rueckert, David Rauber, Max Gutbrod, Danilo Weber Nunes, Christoph Palm

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Raphaela MaerklRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany. raphaela.maerkl@st.oth-regensburg.de.ORCID http://orcid.org/0009-0004-0870-6654
Tobias RueckertRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany.ORCID http://orcid.org/0009-0005-0628-1979
David RauberRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany.ORCID http://orcid.org/0009-0006-1782-5035
Max GutbrodRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany.ORCID http://orcid.org/0009-0003-1451-8361
Danilo Weber NunesRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany.ORCID http://orcid.org/0000-0002-0401-0842
Christoph PalmRegensburg Medical Image Computing (ReMIC), OTH Regensburg, 93053, Regensburg, Germany.ORCID http://orcid.org/0000-0001-9468-2871

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRecognizing previously unseen classes with neural networks is a significant challenge due to their limited generalization capabilities. This issue is particularly critical in safety-critical domains such as medical applications, where accurate classification is essential for reliability and patient safety. Zero-shot learning methods address this challenge by utilizing additional semantic data, with their performance relying heavily on the quality of the generated embeddings.

methodsThis work investigates the use of full descriptive sentences, generated by a Sentence-BERT model, as class representations, compared to simpler category-based word embeddings derived from a BERT model. Additionally, the impact of z-score normalization as a post-processing step on these embeddings is explored. The proposed approach is evaluated on a multi-label generalized zero-shot learning task, focusing on the recognition of surgical instruments in endoscopic images from minimally invasive cholecystectomies.

resultsThe results demonstrate that combining sentence embeddings and z-score normalization significantly improves model performance. For unseen classes, the AUROC improves from 43.9 % to 64.9 %, and the multi-label accuracy from 26.1 % to 79.5 %. Overall performance measured across both seen and unseen classes improves from 49.3 % to 64.9 % in AUROC and from 37.3 % to 65.1 % in multi-label accuracy, highlighting the effectiveness of our approach.

conclusionThese findings demonstrate that sentence embeddings and z-score normalization can substantially enhance the generalization performance of zero-shot learning models. However, as the study is based on a single dataset, future work should validate the method across diverse datasets and application domains to establish its robustness and broader applicability.

Indexed as

EndoscopyNeural Networks, ComputerHumansReproducibility of ResultsSemanticsGeneralized zero-shot learningMulti-label classificationSentence embeddingsSurgical instrumentsZ-score normalization

Identifiers

PMID40498241
PMCPMC12350423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.