Evidence map›Paper›PMID 40497241›Full record

ArticleTherapeutic advances in gastroenterology2025

Intestinal ultrasound measurement of bowel wall thickness can be used as a sole marker for defining anti-TNF maintenance therapy failure in Crohn's disease.

Ahmad Albshesh, Shadi Haj, Ido Veisman, Lior Dar, Shomron Ben-Horin, Ohad Regev, Uri Kopylov, Dan Carter

Abstract read
In one paragraph

Article in Therapeutic advances in gastroenterology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ahmad AlbsheshGastroenterology Institute, Chaim Sheba Medical Center, Derech Sheba 2, Tel HaShomer 6997801, Israel.ORCID https://orcid.org/0000-0001-8962-4263
Shadi HajDepartment of Internal Medicine C, Sheba Medical Center, Tel HaShomer, Israel.
Ido VeismanDepartment of Gastroenterology, Sheba Medical Center, Tel HaShomer, Israel.ORCID https://orcid.org/0000-0003-0490-0607
Lior DarDepartment of Gastroenterology, Sheba Medical Center, Tel HaShomer, Israel.
Shomron Ben-HorinDepartment of Gastroenterology, Sheba Medical Center, Tel HaShomer, Israel.ORCID https://orcid.org/0000-0002-3984-4580
Ohad RegevJoyce & Irving Goldman Medical School, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
Uri KopylovDepartment of Gastroenterology, Sheba Medical Center, Tel HaShomer, Israel.ORCID https://orcid.org/0000-0002-7156-0588
Dan CarterDepartment of Gastroenterology, Sheba Medical Center, Tel HaShomer, Israel.ORCID https://orcid.org/0000-0001-7979-6803

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Bowel wall thickness (BWT) measurements in intestinal ultrasound (IUS) are recognized indicators of inflammatory activity in Crohn's disease (CD). However, the added value of other ultrasonographic parameters for monitoring and predicting treatment failure during anti-tumor necrosis factors' (TNF) maintenance therapy is still not absolutely defined. Objectives: To determine whether BWT, as measured by IUS, can serve as a reliable single marker for predicting treatment failure in CD patients under anti-TNF therapy, compared to a combination of ultrasonographic parameters. Design: This study was a single-center, retrospective cohort study. Methods: This study included 103 CD patients in clinical remission on anti-TNF therapy, who had an IUS examination within 10 months following therapy initiation. We investigated the correlation of these ultrasonographic parameters with subsequent treatment failures, defined by disease flares, and the need for surgery, hospitalization, corticosteroid use, dose escalation, and drug discontinuation. Results: Treatment failure occurred in 59.2% of patients within a median of 5 months post-index IUS. Significant differences were observed in BWT (3.9 mm in the failure group vs 3 mm in the remission group, Conclusion: Our findings suggest that BWT alone may be used as a single ultrasonographic marker of treatment, therefore simplifying the use of IUS. Using a single objective ultrasonographic parameter simplifies the use of IUS, an important factor that can facilitate the use of this important imaging technique.

Indexed as

anti-TNF therapybowel wall thickness (BWT)intestinal ultrasound (IUS)therapy failure

Identifiers

PMID40497241
PMCPMC12149615

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.