Evidence map›Paper›PMID 40493894›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2025

Microplastics in cardiopulmonary bypass: quantification and characterization of particles across systems.

Jordan L Green, Daniel T Field, Robert Bennett, Lauren C Jenner, Emma C Chapman, Laura R Sadofsky, Jeanette M Rotchell, Mahmoud Loubani

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Microplastic in perfusion: the hidden risk and how to address it.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jordan L GreenCentre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK.
Daniel T FieldCentre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK.
Robert BennettCentre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK.
Lauren C JennerHull York Medical School, University of Hull, Hull, UK.
Emma C ChapmanSchool of Natural Sciences, University of Hull, Hull, UK.
Laura R SadofskyHull York Medical School, University of Hull, Hull, UK.
Jeanette M RotchellSchool of Natural Sciences, University of Hull, Hull, UK.ORCID 0000-0002-7371-6080
Mahmoud LoubaniCentre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK.ORCID 0000-0003-1826-6686

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study determines the microplastic (MP) levels, dimension, shape, and chemical composition generated from conventional cardiopulmonary bypass and minimally invasive extracorporeal circulation (MiECC) circuits.

methodsIn vitro conventional and MiECC circuits, mimicking realistic setups with 2 L of Hartmann's solution were run for 90 min (n = 3 circuit runs each), filtered, and analysed using micro-Fourier transform infrared spectroscopy alongside procedural blanks (n = 5).

resultsConventional circuits produced 60.4 ± 7.6 MPs L-1h-1 (77.0% of the total particles). MiECC circuits produced 48.4 ± 31.3 MPs L-1h-1 (45.3% of total particles). MP levels in each circuit type were significantly elevated compared with procedural blank (n = 5) samples (5.6 ± 10.4 MPs L-1h-1) but did not differ with respect to the other. Twenty different MP polymer types were detected whereby polydimethyl siloxane, poly(decyl methacrylate), and poly(N-butyl methacrylate) represented the most MPs within conventional circuits. For MiECC, the most abundant were polypropylene, polyethylene, and polyamide. Average MP lengths differed significantly: 93.5 ± 98.6 µm (conventional) versus 62.0 ± 54.4 µm (MiECC) (P < 0.001), although widths did not differ. Film particles (48.2%) were the predominant shape for conventional circuits and fragments (50.5%) for MiECC.

conclusionsSignificant levels of MP particles were produced across the two systems. Future studies can determine the time points at which they are produced in machine use, to mitigate their production, as well as inform cell/tissue culture investigations into the clinical significance of their introduction into patients undergoing cardiac surgery.

Indexed as

Cardiopulmonary BypassExtracorporeal CirculationMicroplasticsEquipment DesignHumansParticle SizePolymersSpectroscopy, Fourier Transform InfraredMicroplasticsPolymerscardiopulmonary bypassFTIRmicroplasticminimally invasive extracorporeal circulation (MiECC)polymer

Identifiers

PMID40493894
PMCPMC12161987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.