ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2025
The use of FD-HPC in Ruptured and Unruptured Aneurysms, the Italian Dataset (RUAID): Preliminary results on feasibility and safety.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
39 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BackgroundThe introduction of flow diverters (FDs) has revolutionized the treatment of complex intracranial aneurysms; subsequent surface modifications have extended their indications to ruptured, bifurcation, and distal aneurysms. The aim of this study is to assess the real-world feasibility and safety of HPC surface-modified devices in the treatment of ruptured and unruptured aneurysms.MethodsThis independent, multicenter, prospective observational study evaluated the outcomes of patients treated with implanted Phenox p64 or p48 MW-HPC-FDs between 2020 and 2022. The sub-analysis of the procedures, complications (clinical and technical), and additional treatment requirements assessed the devices' feasibility and safety in the peri-procedural period.ResultsOne hundred and forty aneurysms (35% ruptured and 65% unruptured) were treated in 140 patients (37 females and 103 males) using 153 HPC-FDs (111 p64 and 42 p48): 100 aneurysms were saccular (71%), 22 dissecting (16%), 13 fusiform (9%), and five blister-like (3.6%). The successful deployment rate was 97.9%. The overall peri-procedural mortality rate was 9%, including three device-related deaths (2.2%); the overall morbidity rate was 12.1% (6.4% severe, 3.6% mild, and 2.1% asymptomatic adverse events); 4.4% of the clinical adverse events were certainly device related, and 2.2% were probably device related.ConclusionsThe use of p64 and p48 HPC-FDs is highly feasible and acceptably safe, although further data are needed to assess the impact of the coating on safety in emergency and elective procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.