ArticleMedical physics2025

In silico modeling of a clinical photon-counting CT system: Verification and validation.

Cindy McCabe, Brian Harrawood, Ehsan Samei, Ehsan Abadi

Abstract readValidation Study
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Cindy McCabeCenter for Virtual Imaging Trials, Duke University, Durham, North Carolina, USA.
Brian HarrawoodCenter for Virtual Imaging Trials, Duke University, Durham, North Carolina, USA.
Ehsan SameiCenter for Virtual Imaging Trials, Duke University, Durham, North Carolina, USA.
Ehsan AbadiCenter for Virtual Imaging Trials, Duke University, Durham, North Carolina, USA.

Funding

TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Simulation Tools for Dynamic CTR01EB001838 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SAMEI, EHSAN, SEGARS, WILLIAM P · 2005 to 2023
$6.9M
Accuracy and Precision in CT Quantification of COPD Through Virtual Imaging TrialsR01HL155293 · NHLBI · DUKE UNIVERSITY · PI ABADI, EHSAN · 2021 to 2025
$2.2M
NHLBI NIH HHS R01 HL155293NIBIB NIH HHS P41 EB028744NIBIB NIH HHS R01 EB001838NIH HHS P41EB028744NIH HHS R01EB001838NIH HHS R01HL155293
6 · The paper itself

Abstract

backgroundComputed tomography (CT) is rapidly advancing with the recent FDA clearance of photon-counting CT (PCCT) systems for clinical use. New technologies are best evaluated using physical phantoms or patient images. However, both methods have their drawbacks: physical phantoms lack the complexity and diversity to be representative of a human population, and patient images lack the ground truth and are often cost- and time-prohibitive. Virtual imaging trials, also known as in silico trials, can mitigate these limitations by using computer simulations to conduct imaging experiments to assess the safety and efficacy of new medical technologies for specific clinical conditions. However, to date, there have been no simulation platforms to assess PCCT systems generalizable across clinical imaging conditions. PURPOSE: The purpose of this study was to develop and validate a computationally-efficient CT simulator that realistically accounts for conditions of a clinical PCCT system to be used for in silico trials.

methodsThe simulator was built upon a state-of-the-art platform (DukeSim) which simulates CT projection images of computational phantoms given the geometry and physics of the scanner and acquisition settings. To model the photon-counting detection process, we utilized a spatio-energetic detector model based on Monte Carlo simulations with known properties of the detectors. DukeSim was augmented to account for the geometry and physics of a clinical PCCT system (NAEOTOM Alpha, Siemens), including correlated noise between detector thresholds, and low-signal physics for photon starved regions. We validated the simulation platform against experimental measurements using two physical phantoms scanned with a clinical PCCT scanner. The ACR phantom-a cylindrical phantom with four inserts was used to validate the simulator across a clinically relevant dose range with images acquired at four dose levels (CTDI

resultsThe developed simulator generated images that were close to the experimental scans. In terms of noise magnitude, the discrepancy between real and simulated data were 2.78 ± 3.02% and 2.67 ± 1.53%, for the ACR and Mercury phantom, respectively. In terms of the frequency at 50% MTF, the discrepancy between real and simulated data were 0.05 and 0.03 mm

conclusionsWe successfully developed and validated a virtual imaging platform for a current PCCT system, enabling the optimization of imaging parameters (including dose optimization) for specific clinical tasks, as well as comparisons across CT systems.

Indexed as

Computer SimulationPhotonsTomography, X-Ray ComputedHumansMonte Carlo MethodPhantoms, ImagingCT simulatorphoton‐counting CTvirtual imaging trial

Identifiers

PMID40491044
PMCPMC12285274

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.