In silico modeling of a clinical photon-counting CT system: Verification and validation.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950.European radiology · 2026Article
- The Accuracy of Noise Measurements in Patient CT Images.Academic radiology · 2026Article
- Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan.Medical physics · 2026Article
- Truth-based physics informed estimation of material composition in spectral CT in terms of density and effective atomic number.Physics in medicine and biology · 2026Article
- Airway quantifications of bronchitis patients with photon-counting and energy-integrating computed tomography.Journal of medical imaging (Bellingham, Wash.) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundComputed tomography (CT) is rapidly advancing with the recent FDA clearance of photon-counting CT (PCCT) systems for clinical use. New technologies are best evaluated using physical phantoms or patient images. However, both methods have their drawbacks: physical phantoms lack the complexity and diversity to be representative of a human population, and patient images lack the ground truth and are often cost- and time-prohibitive. Virtual imaging trials, also known as in silico trials, can mitigate these limitations by using computer simulations to conduct imaging experiments to assess the safety and efficacy of new medical technologies for specific clinical conditions. However, to date, there have been no simulation platforms to assess PCCT systems generalizable across clinical imaging conditions. PURPOSE: The purpose of this study was to develop and validate a computationally-efficient CT simulator that realistically accounts for conditions of a clinical PCCT system to be used for in silico trials.
methodsThe simulator was built upon a state-of-the-art platform (DukeSim) which simulates CT projection images of computational phantoms given the geometry and physics of the scanner and acquisition settings. To model the photon-counting detection process, we utilized a spatio-energetic detector model based on Monte Carlo simulations with known properties of the detectors. DukeSim was augmented to account for the geometry and physics of a clinical PCCT system (NAEOTOM Alpha, Siemens), including correlated noise between detector thresholds, and low-signal physics for photon starved regions. We validated the simulation platform against experimental measurements using two physical phantoms scanned with a clinical PCCT scanner. The ACR phantom-a cylindrical phantom with four inserts was used to validate the simulator across a clinically relevant dose range with images acquired at four dose levels (CTDI
resultsThe developed simulator generated images that were close to the experimental scans. In terms of noise magnitude, the discrepancy between real and simulated data were 2.78 ± 3.02% and 2.67 ± 1.53%, for the ACR and Mercury phantom, respectively. In terms of the frequency at 50% MTF, the discrepancy between real and simulated data were 0.05 and 0.03 mm
conclusionsWe successfully developed and validated a virtual imaging platform for a current PCCT system, enabling the optimization of imaging parameters (including dose optimization) for specific clinical tasks, as well as comparisons across CT systems.