An Analysis of Scotopic Microperimetry in Healthy Adults.

Daniel A O Adeyoju, Amandeep S Josan, Laura J Taylor, Robert E MacLaren

Abstract read
In one paragraph

Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Daniel A O AdeyojuOxford Eye Hospital, Oxford University Hospitals NHS Trust, Oxford, UK.
Amandeep S JosanOxford Eye Hospital, Oxford University Hospitals NHS Trust, Oxford, UK.
Laura J TaylorOxford Eye Hospital, Oxford University Hospitals NHS Trust, Oxford, UK.
Robert E MacLarenOxford Eye Hospital, Oxford University Hospitals NHS Trust, Oxford, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Scotopic microperimetry measures retinal sensitivity under very low light and may be useful in conditions characterized by nyctalopia, such as retinitis pigmentosa and age-related macular degeneration. The Scotopic Macular Integrity Assessment device enables two-color perimetry to isolate rod and cone responses. This study assesses the reliability, test-retest repeatability, and sensitivity in healthy participants aiming to establish normative values. Methods: Scotopic microperimetry was performed using cyan and red stimuli on a 37-point radial grid after dark adaptation on control participants with no history of eye disease and visual acuity of 0.1 logarithm of the minimum angle of resolution or better. Fixation stability, fixation losses, and identification of the rod-free zone were used as reliability metrics. A subset underwent repeat testing within 4 weeks. Results: Thirty-nine participants (19 male and 20 female), median age 24 years (interquartile range, 9.5 years) and 23 years (interquartile range, 9 years) for the right and left eyes, respectively, completed testing. Overall 77 eyes underwent scotopic testing, with 82% meeting reliability criteria. Mean cyan and red sensitivities were 19.9 ± 1.1 dB and 20.9 ± 1.2 dB in right eyes, and 20.1 ± 1.4 dB and 21.3 ± 1.4 dB in left eyes, respectively. Volumetric cyan and red sensitivities were 2868 ± 157 dB.deg2 and 3077 ± 176 dB.deg2 in the right eyes, respectively, and 2892 ± 205 dB.deg2 and 3126 ± 207 dB.deg2 in the left eyes, respectively. Mean sensitivity coefficients of repeatability (CoR) were ± 1.4 dB (cyan) and ± 2.1 dB (red) while pointwise coefficients of repeatability were ± 7.2 dB (95% confidence interval, 6.5-7.6 dB) for cyan and ± 7.9 dB (95% confidence interval, 7.3-8.4 dB) for red, with no significant differences between eyes or genders. Fixation stability assessed using the 95% bivariate contour ellipse area for cyan was 2.9 ± 5.9 deg2 and 2.3 ± 2.2 deg2 for the right and left eyes, respectively, and for red were 0.7 ± 0.6 deg2 and 0.9 ± 0.8 deg2 for the right and left eyes, respectively. Again, there were no significant differences between cyan and red tests (Friedman test, bivariate contour ellipse area 63%, P = 0.455; bivariate contour ellipse area 95%, P = 0.432). Conclusions: Scotopic microperimetry using the Scotopic Macular Integrity Assessment device was feasible and well-tolerated. Repeatability metrics demonstrated limitations in fine spatial mapping of scotopic retinal sensitivity. Translational Relevance: This study highlights potential areas for future improvements in scotopic microperimetry before its use as an outcome measure in clinical trials for retinal disease.

Indexed as

Night VisionRetinaVisual FieldsVisual Field TestsAdultDark AdaptationFemaleHealthy VolunteersHumansMaleReproducibility of ResultsVisual AcuityYoung Adult

Identifiers

PMID40488699
PMCPMC12177773

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.