Evidence map›Paper›PMID 40487025›Full record

ArticleProceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems2024

Thermal Ablation Therapy Control with Tissue Necrosis-driven Temperature Feedback Enabled by Neural State Space Model with Extended Kalman Filter.

Ryo Murakami, Satoshi Mori, Haichong K Zhang

Abstract read
In one paragraph

Article in Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ryo MurakamiRyo Murakami is with Department of Robotics Engineering, Worcester Polytechnic Institute, 50 Prescott St., Worcester MA, The United States.
Satoshi MoriSatoshi Mori is with No Affiliations, Ehime, Japan.
Haichong K ZhangHaichong K. Zhang is with Department of Biomedical Engineering, Robotics Engineering, and Computer Science Engineering, Worcester Polytechnic Institute, 50 Prescott St., Worcester MA, The United States.

Funding

MR-Guided Precision Conformal Ablation Therapy for Brain TumorsR01CA166379 · NCI · WORCESTER POLYTECHNIC INSTITUTE · PI FISCHER, GREGORY S, PILITSIS, JULIE GEORGIA · 2013 to 2022
$6.5M
PSMA-based Cancer Imaging AgentsR01CA134675 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI POMPER, MARTIN G · 2009 to 2025
$6.2M
Physician Assistance Technology in Image-guided Robotic Intervention of ProstateR01EB030539 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI HATA, NOBUHIKO, ZHANG, HAICHONG · 2021 to 2024
$2.7M
Automatic Wide-Field Optical Coherence Tomography for Assessment of Transplant Kidney ViabilityR01DK133717 · NIDDK · UNIVERSITY OF MASSACHUSETTS AMHERST · PI POTTER, STEVEN, TANG, QINGGONG · 2022 to 2025
$2.5M
Robotic Lung Ultrasound for Triage of COVID-19 Patients in a Resource-Limited EnvironmentDP5OD028162 · OD · WORCESTER POLYTECHNIC INSTITUTE · PI ZHANG, HAICHONG · 2019 to 2023
$2.3M
NCI NIH HHS R01 CA134675NCI NIH HHS R01 CA166379NIBIB NIH HHS R01 EB030539NIDDK NIH HHS R01 DK133717NIH HHS DP5 OD028162
6 · The paper itself

Abstract

Thermal ablation therapy is a major minimally invasive treatment. One of the challenges is that the targeted region and therapeutic progression are often invisible to clinicians, requiring feedback provided in numerical information or imaging. Several emerging imaging modalities offer visualization of the ablation-induced necrosis formation; however, relying solely on necrosis monitoring can result in tissue overheating and endangering patients. Some of the necrosis monitoring modalities are known for their capabilities in temperature sensing, but the principles on which they are based have several limitations, such as sensitivity to the tissue motion and their environment. In this study, we propose a necrosis progression-based temperature estimation technique as an added safety feature for avoiding overheating. This model-based method does not require additional sensing hardware. It is designed to work as an independent estimator or a complimentary estimation component with other thermometers for improved robustness. For this objective, the Neural State Space model is used to approximate the ablation therapy, whose theoretical models involve nonlinear partial differential equations. Then, the Extended Kalman Filter is designed based on the model. The simulation study shows the estimation module robustly estimates the tissue temperature under several types of noise. The maximum estimation error observed before terminating ablation was around 1 °C, and the desired safety feature was successfully demonstrated. The estimator is expected to be used in a variety of necrosis monitoring modalities to guarantee more precise and safer treatment. More ambitiously, the architecture with the Neural State Space model and Extended Kalman Filter is generalizable to other medical/biological procedures involving nonlinear and patient/environment-specific physics and even to procedures having no reliable theoretical models.

Identifiers

PMID40487025
PMCPMC12143415

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.