Evidence map›Paper›PMID 40486795›Full record

ArticleJSES international2025

Errors in implant orientation estimation in novice vs. experienced surgeons during reverse shoulder arthroplasty for a superior glenoid wear pattern.

Ryan Lohre, Aaron J Bois, Akshay Lobo, J Whitcomb Pollock, Peter Lapner, George S Athwal, Danny Goel

Abstract read
In one paragraph

Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ryan LohreDepartment of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, Boston Shoulder Institute, Boston, MA, USA.
Aaron J BoisSection of Orthopaedic Surgery, Department of Surgery, University of Calgary, Calgary, AB, Canada.
Akshay LoboDepartment of Orthopaedics, University of British Columbia, Vancouver, BC, Canada.
J Whitcomb PollockDivision of Orthopaedic Surgery, Ottawa Hospital Research Institute; University of Ottawa, Ottawa, ON, Canada.
Peter LapnerDivision of Orthopaedic Surgery, Ottawa Hospital Research Institute; University of Ottawa, Ottawa, ON, Canada.
George S AthwalRoth McFarlane Hand and Upper Limb Center, Western University Schulich School of Medicine and Dentistry, London, ON, Canada.
Danny GoelDepartment of Orthopaedics, University of British Columbia, Vancouver, BC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Glenoid baseplate orientation in reverse shoulder arthroplasty influences clinical outcomes, complications, and failure rates. This study aimed to determine novice and experienced shoulder surgeon's ability to accurately characterize glenoid component orientation in an intraoperative scenario. Methods: Glenoid baseplates were implanted in 8 fresh frozen cadavers by novice surgical trainees. Glenoid baseplate version, inclination, augment rotation, and superior-inferior center of rotation offset were then measured using in-person visual assessments by novice and experienced shoulder surgeons immediately after implantation. Glenoid orientation parameters were then measured using 3-dimensional (3D) computed tomography (CT) scans with digitally reconstructed radiographs (DRRs) by 2 independent observers with a 1-month time interval between repeat measurements. Bland-Altman plots were produced to determine the accuracy of glenoid orientation using standard intraoperative assessment compared to postoperative 3D CT scan results. Interclass correlation coefficients were produced for measurements, rated as 0.01-0.39 poor, 0.40-0.59 fair, 0.60-0.74 good, and 0.75-1.00 excellent. Results: Visual assessment of glenoid baseplate orientation showed "poor" to "fair" correlation to 3D CT DRR measurements for both novice and experienced surgeon groups for all measured parameters. There was a large discrepancy between intraoperative visual assessments and 3D CT DRR measurements for all parameters. Errors in visual assessment of up to 20° of inclination by experienced surgeons ( Conclusion: Intraoperative measurement errors in glenoid placement are present for both inexperienced and experienced surgeons. Kinesthetic input during implantation may improve orientation understanding.

Indexed as

3D Computed tomographyDigitally reconstructed radiographKinesthetic learningResident trainingReverse shoulder arthroplastySurgical training

Identifiers

PMID40486795
PMCPMC12145070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.