Evidence map›Paper›PMID 40486499›Full record

ArticleX-ray spectrometry : XRS

A Field-based Evaluation of Portable XRF to Screen for Toxic Metals in Seafood Products.

Austin A Roberts, Diana Guimarães, Mina W Tehrani, Shao Lin, Patrick J Parsons

Abstract read
In one paragraph

Article in X-ray spectrometry : XRS. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Austin A RobertsLaboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12237, USA.
Diana GuimarãesLaboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12237, USA.
Mina W TehraniLaboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12237, USA.
Shao LinDepartment of Environmental Health Sciences, University at Albany, Rensselaer, NY 12144, USA.
Patrick J ParsonsLaboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12237, USA.

Funding

Field Validation of New XRF Analyzers: Assessing Personal Exposure to MetalsR01ES020371 · NIEHS · WADSWORTH CENTER · PI PARSONS, PATRICK J. · 2011 to 2012
$758k
FDA HHS U19 FD007089NIEHS NIH HHS R01 ES020371
6 · The paper itself

Abstract

Portable X-Ray Fluorescence (XRF) has become increasingly popular where traditional laboratory methods are either impractical, time consuming and/or too costly. While the Limit of Detection (LOD) is generally poorer for XRF compared to laboratory-based methods, recent advances have improved XRF LODs and increased its potential for field-based studies. Portable XRF can be used to screen food products for toxic elements such as lead (Pb), cadmium (Cd), mercury (Hg), and arsenic (As), manganese, (Mn), zinc (Zn) and strontium (Sr). In this study, 23 seafood samples were analyzed using portable XRF in a home setting. After XRF measurements were completed in each home, the same samples were transferred to the laboratory for re-analysis using microwave-assisted digestion and Inductively Coupled Plasma Tandem Mass Spectrometry (ICP-MS/MS). Four elements (Mn, Sr, As and Zn) were quantifiable by XRF in most samples, and those results were compared to those obtained by ICP-MS/MS. Agreement was judged reasonable for Mn, Sr, and As, but not for Zn. Discrepancies could be due to 1) the limited time available to prepare field samples for XRF, 2) the heterogeneous nature of "real samples" analyzed by XRF, and 3) the small beam spot size (~1mm) of the XRF analyzer. Portable XRF is a cost-effective screening tool for public health investigations involving exposure to toxic metals. It is important for practitioners untrained in XRF spectrometry to (a) recognize the limitations of portable instrumentation, (b) include validation data for each specific analyte(s) measured, and (c) ensure personnel have some training in sample preparation techniques for field based XRF analyses.

Indexed as

arsenicfield validationleadportable XRF

Identifiers

PMID40486499
PMCPMC12143465

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.