Evidence map›Paper›PMID 40485105›Full record

ArticleMagnetic resonance in medicine2025

Strong gradients, cool performance: A 64-channel array coil with concurrent field monitoring and thermal control for ex vivo diffusion-weighted brain imaging using the 3T connectome 2.0 MRI scanner.

Alina Müller, Mirsad Mahmutovic, Mona Alem, Gabriel Ramos-Llordén, Dongsuk Sung, Manisha Shrestha, Sam-Luca J D Hansen, Chaimaa Chemlali, Anpreet Ghotra, Jason Stockmann and 5 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Alina MüllerInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0002-3324-6889
Mirsad MahmutovicInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0001-9178-4194
Mona AlemInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0009-0008-4092-9304
Gabriel Ramos-LlordénAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0003-4020-705X
Dongsuk SungAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0001-6287-2144
Manisha ShresthaInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0009-0004-0066-4066
Sam-Luca J D HansenInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0002-5353-5573
Chaimaa ChemlaliInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0002-2896-7155
Anpreet GhotraInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0001-6445-9062
Jason StockmannAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0001-8454-5347
Choukri MekkaouiAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0001-8597-9219
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0001-8278-6307
Anastasia YendikiAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0003-1386-3828
Susie Y HuangAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0003-2950-7254
Boris KeilInstitute of Medical Physics and Radiation Protection, TH Mittelhessen University of Applied Sciences, Giessen, Hesse, Germany.ORCID https://orcid.org/0000-0003-0805-8330

Funding

CONNECTOME 2.0: DEVELOPING THE NEXT GENERATION HUMAN MRI SCANNER FOR BRIDGING STUDIES OF THE MICRO-, MESO- AND MACRO-CONNECTOMEU01EB026996 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI BASSER, PETER J., HUANG, SUSIE YI · 2018 to 2022
$14.2M
Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Aapo Nummenmaa · 2020 to 2026
$10.9M
Connectome 2.0: A BRAIN Technology Integration and Dissemination Resource for Ultra-High Gradient Magnetic Resonance Imaging of Human Brain Circuits Across ScalesU24NS137077 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI Susie Yi Huang · 2024 to 2026
$4.0M
Revealing the Functional and Microstructural Response of Human Hippocampus to Spatial Learning with High-Gradient Strength Diffusion MRIK99NS132984 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI RAMOS LLORDEN, GABRIEL · 2024 to 2025
$327k
Deutsche Forschungsgemeinschaft INST-169/22-1Hessisches Ministerium für Wissenschaft und Kunst LOEWE/2/16/519/03/09.001(0001)/101Hessisches Ministerium für Wissenschaft und Kunst LOEWE/4TP/I519/05/02.002(0004)/107NIBIB NIH HHS K99NS132984NIBIB NIH HHS P41 EB030006NIBIB NIH HHS P41-EB030006NIBIB NIH HHS U01 EB026996NIBIB NIH HHS U01-EB026996NIBIB NIH HHS U24-NS137077NINDS NIH HHS K99 NS132984NINDS NIH HHS U24 NS137077
6 · The paper itself

Abstract

purposeHigh-resolution ex vivo diffusion-weighted imaging (dMRI) with high

methodsA customized anatomically conformal 64-channel receive array coil with a dedicated Tx birdcage coil was developed for 3T diffusion-weighted imaging of whole human ex vivo brain specimens. Field monitoring capabilities were integrated to correct spatiotemporal field perturbations caused by gradient-induced eddy currents. Temperature stability throughout extended acquisition periods was achieved through an integrated stabilization system. Coil performance was validated through comprehensive measurement of SNR, g-factor maps, field camera free induction decays (FIDs), temperature, mean diffusivity, and fractional anisotropy across multiple diffusion-weighted scans.

resultsThe system demonstrated 73% higher SNR compared with a 72-channel in vivo head coil. Integration of the field camera maintained its FID quality without SNR penalties or significant receive coil coupling effects. Temperature stabilization improved the reliability of quantitative diffusion-weighted measurements by eliminating measurement drift during a 13-hour acquisition, where mean diffusivity and mean kurtosis would have increased by 22% and decreased by 19%, respectively.

conclusionWe describe an integrated hardware approach for addressing higher order field perturbations, thermal instability, and SNR challenges in human ex vivo whole brain dMRI under high-diffusion sensitizing gradient conditions. This approach combines an anatomically optimized multichannel receive array, concurrent field monitoring, and active temperature stabilization. Enhanced image quality and improved reliability of quantitative MR imaging were demonstrated with this comprehensive hardware solution.

Indexed as

BrainConnectomeDiffusion Magnetic Resonance ImagingAnisotropyEquipment DesignHumansImage Processing, Computer-AssistedPhantoms, ImagingReproducibility of ResultsSignal-To-Noise RatioTemperaturediffusion MRIfield monitoringhuman connectomephased array coilradiofrequency coil

Identifiers

PMID40485105
PMCPMC12393195

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.