ArticlePhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)2025
Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study.
Article in Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Optimizing energy settings in CdTe, CZT, and Si photon-counting CT for material separation and detection.Physics in medicine and biology · 2026Article
- Development of a customizable model for spectral photon-counting detector CT.Medical physics · 2025Article
- Liver fat quantification using deep silicon photon-counting CT: anRadiology advances · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeThis study investigates the imaging performance of a deep silicon-based photon-counting CT (Si-PCCT) in quantifying iodine contrast through a virtual imaging trial (VIT).
methodsWe developed a VIT framework using Si-PCCT simulator and benchmarked it against a prototype using an ACR phantom for assessing spatial resolution and noise characteristics, and a geometric phantom for iodine quantification. We imaged geometrical phantoms (20 - 40 cm) with iodine concentrations ranging from 1 to 19.7 mg/ml and XCAT human models with iodine contrast at BMI of 19 to 38 kg/m
resultsThe Si-PCCT simulator closely matched with the prototype, with differences within 3 % in MTF (f
conclusionThis study shows the promising clinical utility of Si-PCCT for accurate iodine quantification under clinically relevant imaging conditions.