ArticleInternational journal on interactive design and manufacturing2023
A study on design, development, optimization and validation of product development framework for humidifier chamber.
Article in International journal on interactive design and manufacturing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The upper airways of the patients under Mechanical Ventilation (MV) cannot humidify the inspired air by themselves, while heat and moisture exchange remain the most important criteria. Insufficient humidification leads to multiple issues while humidifiers, the devices used to add water molecules, gas and temperature, are used in MVs. There is a need exists to develop a new humidifier that can achieve 99% humidity, cost-effective, adheres to ISO standards and compact with controlled design. The aim of the current study is to develop an optimized product development framework for designing the humidifier chamber and to define the product testing guidelines for verification and validation of the humidification chamber. By following a step-wise methodology, the researchers compared the existing samples in the market, conducted CFD analysis for optimization, developed the prototype and framed the guidelines for testing and validation of the humidification chamber. The study found the optimum specifications given herewith as per the outcomes; Inlet/Outlet (mm) should be 22 M, Compressible volume should be 300 ml, Maximum water capacity should be 130 ml while maximum peak flow should be 180 L/min. Further, the resistance to flow should be 10 cm of H
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.