Evidence map›Paper›PMID 40478376›Full record

Article3D printing in medicine2025

Printing outsourced orthognathic surgical splints in-house: a dimensional verification process for point-of-care printing.

Talal Beidas, Luther Light, Caroline Carrico, Shayne Kondor, Prasanth Ravi, Yotom A Rabinowitz

Registry-linked trialAbstract read
In one paragraph

Article in 3D printing in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07079111 (3D Printed Occlusal Splints for Intraoperative Use), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07079111 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

3D Printed Occlusal Splints for Intraoperative Use

TypeinterventionalSponsorJohns Hopkins UniversityRan2026 to 2030Enrolled70ConditionsMalocclusion, Angle Class I, Malocclusion, Angle Class II, Malocclusion, Angle Class IIIArmsFormlabs 3D printed occlusal splint, Industry made occlusal splint
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Talal BeidasDepartment of Oral and Maxillofacial Surgery, Virginia Commonwealth University, Richmond, VA, USA.
Luther LightVirginia Commonwealth University School of Dentistry, Richmond, VA, USA.
Caroline CarricoDepartment of Biostatistics, Virginia Commonwealth University School of Dentistry, Richmond, VA, USA.
Shayne KondorDepartment of Radiology, University of Cincinnati, Cincinnati, OH, USA.
Prasanth RaviDepartment of Radiology, University of Cincinnati, Cincinnati, OH, USA.
Yotom A RabinowitzVCU Dental Building #1, 521 North 11 Street 3rd Floor, Room 315 BOX 980566, Richmond, VA, 23298-05666, USA. rabinowitzy@vcu.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBoth outsourcing virtual surgery planning and 3D printed splint fabrication have become the standard in the field of orthognathic surgery. In-house (IH) adaptation of these presurgical operations requires compliance with regulatory bodies when designing and manufacturing medical-grade products. The purpose of this study is to evaluate the dimensional accuracy of IH 3D printed orthognathic surgical splints within a hybrid workflow for externally designed splints. MATERIALS AND

methodsAn in vitro study was conducted utilizing an outsourced (OS) orthognathic surgical splint file from a previously treated patient. The control group included the splint's original standard tessellation language (STL) file. Experimental groups included: splint (a) milled with zirconia, (b) 3D printed on a Phrozen 4 K (commercial printer), (c) 3D printed on Formlabs 3B+ (Formlabs 3B + have track record of having FDA cleared materials and workflows in dental applications and have potential materials that could be used for IH manufacturing for orthognathic splints upon further testing and FDA clearance). Surface area analysis was performed using 3-Matic (Materialise© Mimics Software) to generate root mean square (RMS) values between digital copies of the splints and their corresponding original STL files.

resultsThe RMS error in equipment processing and analysis was measured at 0.10 mm. Accounting for this error, the 3D-printed splints exhibited an average RMS of 0.20 mm for both the Formlabs 3B + and the Phrozen 4 K. No statistically significant difference was found between splints from different printers or replicas.

conclusionThis study presents a verification process for providers to verify the geometric stability and reproducibility of their IH-printed orthognathic splints (RMS 0.20 mm). Clinicians may find this study useful when crafting a regulatory-compliant process for the IH manufacturing of OS orthognathic surgery splints.

Indexed as

In-houseOrthognathic splintsOrthognathic surgeryPoint-of-careRegulatory complianceVirtual surgical planning

Identifiers

PMID40478376
PMCPMC12143043

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.