Evidence map›Paper›PMID 40478318›Full record

SynthesisEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2025

Safety profiles of bone-conduction hearing implants revisited: A meta-analytic comparison adjusted for follow-up time.

Marco Caversaccio, Wilhelm Wimmer, Annegret Hoch, Thomas Dejaco, Burkard Schwab

Erratum issuedAbstract readMeta-AnalysisSystematic ReviewComparative Study
In one paragraph

Synthesis in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Marco CaversaccioDepartment of Otorhinolaryngology- Head and Neck Surgery, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland. marco.caversaccio@insel.ch.ORCID http://orcid.org/0000-0002-7090-8087
Wilhelm WimmerDepartment of Otorhinolaryngology, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany.ORCID http://orcid.org/0000-0001-5392-2074
Annegret HochMED-EL Elektromedizinische Geräte GmbH, Innsbruck, Austria.
Thomas DejacoMED-EL Elektromedizinische Geräte GmbH, Innsbruck, Austria.ORCID http://orcid.org/0000-0002-2896-1669
Burkard SchwabHNO-Klinik, Helios Klinikum Hildesheim, Hildesheim, Germany.ORCID http://orcid.org/0000-0002-6013-7952

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo estimate incidence rates of adverse events associated with bone-conduction hearing implants from primary literature and to compare rates among different technological designs.

methodsA systematic literature review and meta-regression was conducted to estimate incidence rates of minor and major complications and their consequences (i.e., revision surgery, explantation, re-implantation and becoming a non-user) while testing for effects of device design, age group, mean follow-up time and study type. These four designs of bone-conduction systems were included: 1) active transcutaneous with electromagnetic transducer (aBCIem), 2) active transcutaneous with piezoelectric transducer (aBCIpz), 3) passive transcutaneous (tBAHA), and 4) passive percutaneous (pBAHA).

resultsThe final dataset included 170 articles reporting on 6451 implantations and 1847 minor and 668 major events. Mean follow-up time was a significant predictor of incidence rates (p < 0.001), with lower rates reported in studies with longer follow-up times. After adjusting to the median follow-up time, the pooled incidence rate of minor complications was significantly lower in aBCIem (p < 0.05) compared to other designs. For both major events and revision surgery, pooled incidence rates were significantly higher in pBAHA compared to aBCIem (p < 0.001) and tBAHA (p < 0.001), but not compared to aBCIpz (Major: p = 0.197; Revision: p = 0.248). Becoming a non-user occurred significantly more frequently in tBAHA compared to other designs (p < 0.005). No statistically significant differences were found in rates of explantation and explantation with re-implantation.

conclusionWhen comparing across multiple studies, adverse event rates should be adjusted for different lengths of follow-up. Synthesizing published evidence without considering follow-up time may lead to false conclusions.

Indexed as

Bone ConductionHearing AidsPostoperative ComplicationsFollow-Up StudiesHumansProsthesis DesignReoperationAdverse eventBone-conduction implantMeta-regressionSafety

Identifiers

PMID40478318
PMCPMC12605608

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.