Evidence map›Paper›PMID 40478154›Full record

ArticleJournal of building engineering2023

Identification of source location in a single-sided building with natural ventilation: Case of interunit pollutant dispersion.

Yuwei Dai, Fuyao Zhang, Haidong Wang

Abstract read
In one paragraph

Article in Journal of building engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuwei DaiSchool of Environment and Architecture, University of Shanghai for Science and Technology, 516 Jungong Rd, Shanghai, 200093, China.
Fuyao ZhangSchool of Environment and Architecture, University of Shanghai for Science and Technology, 516 Jungong Rd, Shanghai, 200093, China.
Haidong WangSchool of Environment and Architecture, University of Shanghai for Science and Technology, 516 Jungong Rd, Shanghai, 200093, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A sudden outbreak of COVID-19 occurred in December 2019 and its rapid spread over the last two years caused a global pandemic. A special airborne transmission via aerosols called interunit dispersion is risky in a high-density urban environment, which needs more attention. In order to identify the source location of pollutants or viruses under the interunit transmission condition with natural ventilation, this study adopted the inverse Computational Fluid Dynamics (CFD) simulation with the adjoint probability method. The detailed process of the inverse modeling was presented. Also, the possible interunit transmission routes of the pollutants or viruses were analyzed. A three-story building model with single-sided openings was built. Six different combinations of fixed sensor locations were tested, and it was determined that setting sensors in the four corner regions of the building was the optimist strategy. A total of 25 cases with five different wind directions (

Indexed as

Coupled indoor and outdoor environmentInterunit dispersionInverse CFD modelingNatural ventilationSource identification

Identifiers

PMID40478154
PMCPMC9896858

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.