ArticleCase studies in thermal engineering2022

A case study on development of thermodynamic entropy measuring device and its implication on the human body.

Selvakumar Pandiaraj, Kumaresan Govindasamy, Anand Pandey, Chandrakant Sonawane, Ali Jawad Alrubaie, Ali Majdi, Mohamed A Mohamed, Mustafa Musa Jaber, Suresh Muthusamy, Hitesh Panchal

Abstract read
In one paragraph

Article in Case studies in thermal engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Selvakumar PandiarajDepartment of Mechanical Engineering, Kongu Engineering College (Autonomous), Perundurai, Erode, Tamil Nadu, India.
Kumaresan GovindasamyDepartment of Mechanical Engineering, Bannari Amman Institute of Technology (Autonomous), Sathyamangalam, Erode, Tamil Nadu, India.
Anand PandeyMechanical Engineering Dept, Symbiosis Institute of Technology, Symbiosis International (Deemed University), Pune, India.
Chandrakant SonawaneMechanical Engineering Dept, Symbiosis Institute of Technology, Symbiosis International (Deemed University), Pune, India.
Ali Jawad AlrubaieDepartment of Medical Instrumentation Techniques Engineering, Al- Mustaqbal University College, 51001, Hilla, Iraq.
Ali MajdiDepartment of Building and Construction Techniques Engineering, Al- Mustaqbal University College, 51001, Hilla, Iraq.
Mohamed A MohamedDepartment of Medical Instruments Engineering Techniques, Al-Turath University College, Baghdad, 10021, Iraq.
Mustafa Musa JaberDepartment of Medical Instruments Engineering Techniques, Dijlah University College, Baghdad, 10021, Iraq.
Suresh MuthusamyDepartment of Electronics and Communication Engineering, Kongu Engineering College (Autonomous), Perundurai, Erode, Tamil Nadu, India.
Hitesh PanchalDepartment of Mechanical Engineering, Government Engineering College, Patan, Gujarat, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the field of thermodynamics, entropy is a measure of the degree of disorder of the system considered focus. The direct measurement of entropy for microscopic systems involving molecule-level variations exists. However, for a macroscopic system, it still remains a challenge. The temperature reading is used as the primary index for understanding the quality of heat. In certain applications, the induced errors in the temperature measurement create complexity in decision making. One such case is the measurement of human body temperature for fever-like symptoms. This research aims to develop a direct entropy measuring device to indicate heat transfer for macroscopic systems. The developed device measured the mean entropy of the human body as 0.042 and 0.146 kJ/K during the daytime and nighttime, respectively. In comparison to the simulated entropy values, the measured values differed by 4% during the trials on the human body. Key decisions on macroscopic systems based on mild temperature variations can be made confidently with the measured entropy values.

Indexed as

Body temperatureEntropy measurementEnvironment-induced errorsInfraredThermodynamics