Evidence map›Paper›PMID 40476013›Full record

ArticleJournal of experimental orthopaedics2025

Change of force and lever arm of the hip abductors after subtrochanteric de-/rotational osteotomy.

Christoph Zindel, Patrick O Zingg, Michel Meisterhans, Samuel Haupt, Armando Hoch, Andreas Flury

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christoph ZindelDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0002-6253-9824
Patrick O ZinggDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0003-0300-3576
Michel MeisterhansDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0002-2478-3877
Samuel HauptDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0002-8419-2489
Armando HochDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0002-9600-4190
Andreas FluryDepartment of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.ORCID https://orcid.org/0000-0003-0350-8101

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Previous studies have shown that rotational osteotomy of the femur reliably corrects anatomical torsion but may result in a ±1 cm antero-posterior shift of the greater trochanter (GT) per 10° of torsional correction. It is unclear whether an inadvertent displacement of the GT following surgical treatment of femoral maltorsion affects the hip abductors in a clinically relevant manner and needs to be addressed by compensatory digastric trochanteric osteotomy. The aim of this study was to investigate the influence of rotational subtrochanteric osteotomy on hip abductor force generation using three-dimensional (3D) surface models. Methods: A 3D statistical shape model (SSM) of a hip/femur was used. From a baseline value of 12°, the SSM was derotated/rotated in 10° increments, creating five different scenarios of anatomical femoral torsion: 32°, 22°, 12° (baseline), 2°, -8° (corresponding to 8° of retro torsion). The origins and insertions of the gluteus medius (GMed) and minimus (GMin) muscles were created. The hip abductor moment was defined as the muscle force (of the hip abductor muscles) multiplied by the force ratio in the direction of abduction (FRDA) multiplied by the lever arm. All values were measured, whereas muscle strength was defined as the length of the muscle fibres in relation to their optimal length. Results: Results indicated minimal changes in muscle length (±1.2%) and FRDA (1.7% to -7%) for GMed und GMin across all scenarios. However, lever arm demonstrated variations (21% to -10%), with an increase observed for derotational osteotomies and a decrease for rotational osteotomies. Conclusion: Subtrochanteric osteotomy in the management of femoral maltorsion affects the hip abduction moment solely through the altered lever arm. A 20° derotation for increased femoral torsion (FT) corresponds to a 20% increase in abduction force of the GMed (improved lever arm), whereas a 20° rotation for decreased FT reduces the abduction force by 10%. Level of Evidence: Level III, diagnostic.

Indexed as

3D analysisabductor forcesubtrochanteric osteotomy

Identifiers

PMID40476013
PMCPMC12138280

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.