ArticleJournal of applied crystallography2025
A SAXS/WAXD beamline with laboratory SAXS apparatus at NanoTerasu.
Article in Journal of applied crystallography, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Introduction to the special issue related to the 19th International Small Angle Scattering Conference (SAS2024).Journal of applied crystallography · 2025Article
- Fast calculation of small-angle scattering profiles of dense protein solutions modeled at the all-atom level.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
NanoTerasu is a new 3 GeV synchrotron radiation facility in Sendai, Japan, which began user operation in April 2024. A station for small-angle X-ray scattering (SAXS) and wide-angle X-ray diffraction (WAXD) has been built at the wiggler beamline BL08W. The station was built in a branch for which an X-ray beam is provided by Bragg reflection from two Si crystals. The X-ray energy is 8.0 or 13.1 keV using either an Si(111) or an Si(220) crystal, respectively. The beam is focused with an Ru-coated bent cylindrical mirror. In the SAXS station, an Anton Paar SAXSpoint 5.0 laboratory X-ray apparatus has been installed. The original X-ray generator and focusing mirror in the laboratory equipment were removed and four-quadrant slits and an ion chamber have been installed. Low-scatter slits in SAXSpoint 5.0 are used as guard slits in front of the sample. The X-ray detector is a DECTRIS Eiger2 1M. The slits, sample and detector are enclosed in a vacuum chamber to reduce scattering from the air. The detector can be moved along the X-ray axis under vacuum to change the sample-to-detector distance between 53 and 1610 mm. The X-ray flux at 8.0 keV is 1.0 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.