Evidence map›Paper›PMID 40473729›Full record

ArticleScientific reports2025

Proof of concept measurement of ovine intertrochanteric fracture stability with an X-ray visualized implantable screw bending sensor.

Nathan T Carrington, Savannah R Forrester, Paul W Milhouse, Caleb J Behrend, Tom B Pace, Kyle Jeray, Jeffrey N Anker, John D DesJardins

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nathan T CarringtonDepartment of Chemistry, Clemson University, Clemson, SC, USA.
Savannah R ForresterAravis BioTech LLC, Greenville, SC, USA.
Paul W MilhouseDepartment of Chemistry, Clemson University, Clemson, SC, USA.
Caleb J BehrendOrthoArizona, Phoenix, Arizona, USA.
Tom B PacePrisma Health, Greenville, SC, USA.
Kyle JerayPrisma Health, Greenville, SC, USA.
Jeffrey N AnkerDepartment of Chemistry, Clemson University, Clemson, SC, USA.
John D DesJardinsAravis BioTech LLC, Greenville, SC, USA. jdesjar@clemson.edu.

Funding

Targeted Nano-therapeutics for Neural RegenerationP20GM103444 · NIGMS · CLEMSON UNIVERSITY · PI MARKWALD, ROGER R, VYAVAHARE, NAREN R · 2012 to 2018
$14.9M
X-ray Visualized Implanted Sensor for Prosthetic Joint Infection (X-VIS-PJI)R43AR081748 · NIAMS · ARAVIS BIOTECH, LLC · PI ANKER, JEFFREY N, CALCUTT, LINDSEY SANDERS · 2022 to 2022
$300k
NIAMS NIH HHS NIH NIAMS R43AR081748NIAMS NIH HHS R43 AR081748NIGMS NIH HHS NIH NIGMS 5P20GM103444NIGMS NIH HHS P20 GM103444
6 · The paper itself

Abstract

Bone healing after internal fixation of intertrochanteric hip fractures is difficult to monitor with radiography, particularly with sliding hip screws (SHS). In this proof-of-concept study, we develop an ovine hip fracture model and use it to evaluate a novel sliding hip screw system with a sensor that can non-invasively detect bending of the screw implant during healing. An existing SHS implant was modified and implanted in a Suffolk Ewe sheep. A straight, radiodense 1 mm tungsten rod was attached to the screw in the cannula to enable quantification of screw bending by radiographically observing relative position of the rod compared to the screw tip. After surgery, weekly loaded and unloaded radiographs were taken of the femur. Once fracture stabilization had been indicated for at least three weeks, the femur was extracted and potted and radiographs were taken under simulated axial loading from 5 to 400 N. By week 3, full in vivo weight bearing over the fractured femur was achieved. In response, implant loading was clearly observed with the novel sensor. This observed implant loading continued until week 8, wherein it ceased entirely. Upon extraction, the femur showed a fully developed and very stable callus surrounding the fracture site. Subsequent mechanical tests confirmed no measurable implant loading under axial loads of up to 400 N. This test indicates that the proposed ovine model produces sufficient force over an SHS implant in an induced fracture. This allowed our sensor to indicate fracture healing through radiography in load scenarios greater than 25 kg.

Indexed as

Bone ScrewsFracture Fixation, InternalHip FracturesAnimalsBiomechanical PhenomenaFemaleFemurFracture HealingProof of Concept StudyRadiographySheepWeight-BearingBoneDiagnostic imagingFractureHip

Identifiers

PMID40473729
PMCPMC12141626

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.