Evidence map›Paper›PMID 40473632›Full record

ArticleScientific reports2025

Robust super-twisting algorithm-based single-phase sliding mode frequency controller in power systems integrating wind turbines and energy storage systems.

Van Van Huynh, Shahalam Naqvi, Bang Le-Huy Nguyen, Anh-Tuan Tran, Jae Woong Shim, Ton Duc Do

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Van Van HuynhModeling Evolutionary Algorithms Simulation and Artificial Intelligence, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam.
Shahalam NaqviDepartment of Energy Operations, Stanford University, Stanford, CA, 94305, USA.
Bang Le-Huy NguyenInstitute of Research and Development, Duy Tan University, Da Nang, 550000, Vietnam.
Anh-Tuan TranModeling Evolutionary Algorithms Simulation and Artificial Intelligence, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City, Vietnam.
Jae Woong ShimDepartment of Electrical Engineering, Sangmyung University, Seoul, 03016, South Korea. jaewshim@smu.ac.kr.
Ton Duc DoDepartment of Robotics and Mechatronics, School of Engineering and Digital Sciences (SEDS), Nazarbayev University, Astana, 010000, Kazakhstan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Frequency regulation in multi-area power systems (MPSs) faces increasing challenges due to the integration of renewable energy sources, such as wind power, and the dynamic behavior of energy storage systems (ESSs). These challenges are further compounded by disturbances from tie-line power exchanges, wind power fluctuations, and variations in battery and flywheel storage. To address this, this paper proposes a robust sliding mode control (SMC) strategy based on a proportional-derivative sliding surface (PD-SS) structure for load frequency control (LFC), leveraging a single-phase approach enhanced by an improved super-twisting algorithm (ISTA). A reduced-order LFC model is introduced to effectively characterize the frequency dynamics. The proposed model explicitly considers lumped disturbances including tie-line power exchanges, wind power fluctuations, and power variations in ESSs of battery and flywheel. A novel SMC scheme is therefore designed based on the simplified model, where the PD-SS structure and single-phase approach eliminate reaching time, ensure immediate trajectory convergence and improve transient performance. An improved super-twisting control law is developed to further enhance robustness by effectively mitigating chattering and oscillation in system dynamics under uncertainties. The global stability of the proposed control strategy is mathematically verified via Lyapunov stability theory. Simulation results under step and stochastic load variations show that the proposed method achieves up to 56% and 84.5% reduction in overshoot compared to PD and PI SMC schemes, respectively, along with a 54.5% improvement in settling time over the PI SMC scheme, thereby confirming its enhanced performance and robustness relative to existing control strategies.

Indexed as

Load frequency controlMultiarea power systemsSliding mode control

Identifiers

PMID40473632
PMCPMC12141675

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.