Myocardial perfusion mapping with intra-arterial spin labeling: Optimization of the labeling efficiency.

Felix Spreter, Johannes Fischer, Ali Caglar Özen, Alexander Maier, Michael Bock, Simon Reiss

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Felix SpreterDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0009-0006-2929-9343
Johannes FischerDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0000-0003-1499-6163
Ali Caglar ÖzenDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0000-0003-3536-0826
Alexander MaierDepartment of Cardiology and Angiology, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0000-0003-0200-7495
Michael BockDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0000-0001-9720-3506
Simon ReissDivision of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.ORCID 0000-0003-2449-1679

Funding

Deutsche Forschungsgemeinschaft RE 4876/1-1Deutsche Forschungsgemeinschaft SFB1425 #422681845
6 · The paper itself

Abstract

purposeIntra-arterial spin labeling (iASL) applies a labeling pulse from a transmit coil at the tip of the catheter for regional myocardial perfusion measurements during MR-guided catheterizations. This study investigates the labeling efficiency of catheter-mounted coils under varying conditions to enable robust iASL measurements.

methodsThe labeling efficiency was assessed by analytical calculations, numerical simulations, and in vitro measurements at 3 T. Analytical solutions were provided for various simplified

results

conclusioniASL creates a saturation that is robust against variations in flow and coil positioning. The simulations could determine the threshold pulse power for robust iASL excitation, which needs to be adapted to applications in different vessels. Thus, iASL may provide an efficient alternative to perfusion measurements with exogenous contrast agents during MR-guided interventions.

Indexed as

Magnetic Resonance AngiographyMyocardial Perfusion ImagingAlgorithmsBlood Flow VelocityComputer SimulationHumansImage EnhancementPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificitySpin LabelsSpin LabelsASLcardiacinterventionalMRI